Operation and Maintenance Manual - EN
This means that if the output for the external conveyor gets damaged, the reserve will be switched
off automatically. This function is suitable in situations when you need to control another external
conveyor that supplies (feeds) pellets from a larger distance to the main conveyor from which the
pellets fall directly to the burner.
f) S67 = 15
….. Reserve function for the compressor control during the function for automatic
burner cleaning using compressed air. Power element designed for switching and powering the
compressor (e.g. contactor) must be connected between reserve output R5 and the compressor.
This function is connected with S68, S41, S42, S43, S44, S45, S46, S47 parameter, which must be
checked and configured.
g) S67 = 16
….. Reserve function for controlling el.fan during the function for automatic burner
cleaning using compressed air. This function is connected with S68, S41, S42, S43, S44, S45, S46,
S47 parameter, which must be checked and configured.
Special function for turning on reserve output R5 according to the temperature of a concrete sensor:
a) e.g. function:
TS>……. means that if the TS sensor temperature is higher then the set value in
S48 parameter – Temperature A, reserve output R5 will be activated
b) e.g. function:
TS<……. means that if the TS sensor temperature is higher then the set value in
S48 parameter – Temperature A, reserve output R5 will be deactivated
c) e.g. function:
TS,TV>……. means that if the TS and TV sensor temperature is higher at the
same time then the set value in S48 parameter – Temperature A and S50 – Temperature B, reserve
output R5 will be activated (Temperature A = first position (TS), Temperature B = second position
(Tv)).
d) e.g. function
TS,TK<……. means that if the TS and TK sensor temperature is higher at the
same time then the set value in S48 parameter – Temperature A and S50 – Temperature B, reserve
output R5 will be deactivated (Temperature A = first position (TS), Temperature B = second po-
sition (Tk)).
Individual functions:
(17) TS>
(18) TS<
(19) TV>
(20) TV<
(21) TK>
(22) TK<
(23) TSV>
(24) TSV<
(25) TS,TV>
(26) TS,TV<
(27) TS,TK>
(28) TS,TK<
(29) TS,TSV>
(30) TS,TSV<
(31) TV,TK>
(32) TV,TK<
(33) TV,TSV>
(34) TV,TSV<
(35) TK,TSV>
(36) TK,TSV<
Summary of Contents for A85
Page 1: ...Operation and Maintenance Manual EN www atmos cz Operation and Maintenance Manual ...
Page 2: ...www atmos cz Operation and Maintenance Manual EN ...
Page 61: ...Operation and Maintenance Manual EN EN www atmos cz EN 61 20 Expanded view of the burner ...
Page 66: ...EN www atmos cz 66 EN Operation and Maintenance Manual EN Notes ...