background image

 

10 

AVR1306 

4.1  16-bit Read 

Figure 4-1 illustrates how to perform a 16-bit read of CNT, and what happens 
internally: 

1. Read CNTL. This will cause the contents of CNTH to be transferred to TEMP in the 

same clock cycle. 

2. Read CNTH. This will automatically cause the contents of TEMP to be read instead 

of the current value of CNTH. 

The result is a snapshot of the 16-bit CNT[H:L] value at the time CNTL was read. 

Figure 4-1. 

16- bit read access. 

CNTH

CNTL

TEMP

Rn

CNTH

CNTL

TEMP

R(n+1)

Rn

R(n+1)

1

2

 

4.2 16-bit Write 

Figure 4-2 illustrates how to perform a 16-bit and what happens internally: 

1. Write CNTL. This will cause the TEMP register to be updated with the new value 

for CNTL. 

2. Write CNTH. This will cause CNTL to be updated with the contents of the TEMP 

register at the same time as CNTH is updated. 

The result is that the 16-bit CNT[H:L] value is updated in the same clock cycle. 

8045A-AVR-02/08 

Summary of Contents for AVR1306

Page 1: ...ch Timer 1 Double buffered 32 bit operation with 32 bit input capture by timer cascading Event counter Timer overflow and error interrupts and events Input capture interrupts and events 1 Introduction...

Page 2: ...to I O pin Typical applications include Timing Periodic interrupt event generation Pulse Width Modulation Event time stamping Event counting Signal parameter measurements Period duty cycle etc 3 1 Tim...

Page 3: ...ed TC_CSEL_DIV1_gc fCLK SYS TC_CSEL_DIV2_gc fCLK SYS 2 TC_CSEL_DIV4_gc fCLK SYS 4 TC_CSEL_DIV8_gc fCLK SYS 8 TC_CSEL_DIV64_gc fCLK SYS 64 TC_CSEL_DIV256_gc fCLK SYS 256 TC_CSEL_DIV1024_gc fCLK SYS 102...

Page 4: ...ister CCxBUF H L Double buffered registers are covered in detail in section 3 7 When used for input capture the value of the PER register determines how input capture values are interpreted If bit 15...

Page 5: ...h buffer register has a related buffer valid flag in the CTRLE register The buffer valid flag is set when a new value is written to the corresponding buffer register The flag is cleared when the buffe...

Page 6: ...the counter value while the counter is running is allowed The write access has higher priority than count clear or reload and will be immediate However if the value written is outside the BOTTOM TOP...

Page 7: ...s Figure 3 4 shows in this mode of operation the counter counts from BOTTOM to TOP then restarts from BOTTOM The waveform generator output is set on the compare match between the count and compare reg...

Page 8: ...hown in Figure 3 5 The counter counts repeatedly from BOTTOM to TOP and then to BOTTOM When the counter hits BOTTOM or TOP the counter changes direction immediately holding the BOTTOM and TOP values f...

Page 9: ...pdate command only has effect on the PERBUF PER registers See section 3 7 for more information about double buffered registers 3 9 2 Force Restart The Force restart command clears the CNT H L register...

Page 10: ...apshot of the 16 bit CNT H L value at the time CNTL was read Figure 4 1 16 bit read access CNTH CNTL TEMP Rn CNTH CNTL TEMP R n 1 Rn R n 1 1 2 4 2 16 bit Write Figure 4 2 illustrates how to perform a...

Page 11: ...tes the write operation by writing to CNTH causing the corrupted low byte to be transferred from TEMP to CNTL There are two possible solutions to this problem 1 Make sure that every 16 bit access is p...

Page 12: ...ded in this way Figure 5 1 Cascading two 16 bit Timer Counter modules TCC1H TCC1L TCC0H TCC0L High word Overflow OVF EVMUX0 Low word OVF Clock signal for high word T C 5 2 Accessing the 32 bit Value W...

Page 13: ...nterrupt event occurs 2 Start TC by selecting a clock source CLKSEL in CTRLA In this configuration the current timer value can be read directly from the CNT H L register The TC overflow bit indicates...

Page 14: ...ite the new compare value to CCA H L 8 Wait for the TC Overflow Flag to be set OVFIF in INTFLAGS 9 Clear the TC Overflow flag 10 Go to step 6 Using this sequence the compare value will be updated once...

Page 15: ...register 11 Read high word input capture value from the TCC1 CCA H L register 12 Combine low word and high word to a 32 bit input capture value 13 Go to step 9 7 Advanced Features In this application...

Page 16: ...ten in ANSI C and should compile on all compilers with XMEGA support Note that this driver is not written with high performance in mind It is designed as a library to get started with the XMEGA Timer...

Page 17: ...ARRANTY RELATING TO ITS PRODUCTS INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIR...

Reviews: