Installation
36
PVL14OF-EXT
7.17.2 Cable For Proper Installation
There will be some initial stretching of the cables in the
beginning. It will be necessary to re-adjust the cables a week
after the fi rst week, then three months thereafter. Failure to do
this will cause uneven lifting.
• Check to make sure that all cables are routed correctly and are on the
correct pulleys.
• Check that all cables are adjusted in the same tension and the lift can be
raised evenly. If not, make the adjustment.
7.17.3 Safety Lock For Proper Installation
• Check to make sure that all air hoses are connected properly and the air
pressure is set to 6-8bar.
• Check to make sure that the control valve for proper operation.
• Check if four latches are engaging uniformly. If not, make the adjustment.
7.17.4 Hydraulic System For Proper Operation
• Proper oil level in the tank, refi ll if needed.
• Raise the lift to the full height and keep the motor running for 5 seconds
and check all hoses connections no leakage. Tighten the connections or
reseal if necessary.
• Check the lift for reaching its maximum height.
If the vented cap is lost or broken, order the replacement. The oil
tank must be vented well.