Installation Steps
32
PV-15PX
R. Tighten All Of The Hydraulic Fittings, And Fill
The Reservoir With Hydraulic Oil (App. 4 Gal.)
Note: For the best motor performance, use AW32 series hydraulic oil.
Install Electrical System
Connect the power source according to the data plate on the Power Unit.
1. Power supply wire (Fire wire L) is connected with wire 4# of control button.
2. Wire 3# of control button is connected with wire 6# of the motor.
3. Wire 5# of the motor is connected with Power supply wire (Null wire N).
Fig. 39
Summary of Contents for PV-15PX
Page 32: ...PV 15PX Exploded View 33 PV 15PX PV 15PX Exploded View Fig 40 ...
Page 33: ...PV 15PX Exploded View 34 PV 15PX Cylinders Fig 41 ...
Page 34: ...PV 15PX Exploded View 35 PV 15PX ATLAS Manual power unit Fig 42 220V 60HZ Single Phase Fig 42 ...
Page 35: ...PV 15PX Exploded View 36 PV 15PX Illustration Of Hydraulic Valve Fig 43 ...