Test Run
37
PV-15PX
Test Run
1. Adjust equalizing cables (See Fig. 44)
Use a wrench and hold the cable fi tting,
meanwhile use a ratchet to tighten the cable
nut. Make sure the two cables have the same
tension and the two carriages lift at the time.
Replace the cover on the lifting head.
2. Adjust safety lock cable
Lift the carriages and lock at the same height, pull the safety cable and then
release a little, and then tighten the cable nuts. Make sure the safety locks click
at the same time.
3. Bleeding the cylinders
This hydraulic system is designed to bleed
air by loosening the bleeding screw. Lift the
carriages to about 12 inches and loosen the
bleeding plugs. Lower the lift until hydraulic
fl uid seeps from the tops of the cylinders, then
tighten the plugs. (See Fig. 45).
Cable nut
Lock nut
Fig. 44
Fig. 45
Bleeding
plug
Summary of Contents for PV-15PX
Page 32: ...PV 15PX Exploded View 33 PV 15PX PV 15PX Exploded View Fig 40 ...
Page 33: ...PV 15PX Exploded View 34 PV 15PX Cylinders Fig 41 ...
Page 34: ...PV 15PX Exploded View 35 PV 15PX ATLAS Manual power unit Fig 42 220V 60HZ Single Phase Fig 42 ...
Page 35: ...PV 15PX Exploded View 36 PV 15PX Illustration Of Hydraulic Valve Fig 43 ...