Installation Requirement
7
PV-15PX
Concrete Specifi cations (See Fig. 4)
Concrete specifi cations must be adhered to the following specifi cations.
Failure to do so may result in lift and/or vehicle falling.
1. Concrete must have 6 inches minimum and must be totally cured before lift
installation.
2. Concrete must be in good condition and must have a test strength of 3,000psi
minimum.
3. Floors must be level with no cracks or holes.
Fig.4
Power Supply
220 volt single phase 30 amp breaker with minimum of 10 gauge wire