- 59 -
6.3.2
Alarm overview Lc1003™
6.3.2.1
Warning alarm icons
Warnings are non-critical alarm conditions and do not affect the operation of the light tower, they serve to draw the operators attention to an undesirable condition. By
default, warning alarms are self-resetting when the fault condition is removed.
Display
Description
Reason
Fail to stop
The module has detected a condition that indicates that the engine is running when it has been
instructed to stop.
Charge failure
The auxiliary charge alternator voltage is low as measured from the W/L terminal.
Low fuel level
The level detected by the fuel level sensor is below the low fuel level setting.
Battery Under Voltage
The DC supply has fallen below or risen above the low volts setting level.
Battery Over Voltage
The DC supply has risen above the high volts setting level.
Generator Under Voltage
The generator output voltage has fallen below the pre-set pre-alarm setting after the Safety On
timer has expired.
Generator Over Voltage
The generator output voltage has risen above the pre-set pre-alarm setting.
‘Fail to Stop’ could indicate a faulty oil pressure sensor. If the engine is at
rest, check the oil sensor wiring and configuration.
00_00_HiLight H6+_EN.book Page 59 Friday, June 4, 2021 11:52 AM
Summary of Contents for HiLight H6+ DC
Page 2: ...00_00_HiLight H6 _EN book Page 2 Friday June 4 2021 11 52 AM ...
Page 94: ... 94 ON ROAD UNDERCARRIAGE LED 00_00_HiLight H6 _EN book Page 94 Friday June 4 2021 11 52 AM ...
Page 96: ... 96 00_00_HiLight H6 _EN book Page 96 Friday June 4 2021 11 52 AM ...
Page 97: ... 97 Circuit diagrams 00_00_HiLight H6 _EN book Page 97 Friday June 4 2021 11 52 AM ...
Page 112: ... 112 00_00_HiLight H6 _EN book Page 112 Friday June 4 2021 11 52 AM ...
Page 115: ...00_00_HiLight H6 _EN book Page 115 Friday June 4 2021 11 52 AM ...