- 21 -
2.4.2
Lc1003™ control and indicator
panel
Overview control panel
For more advanced light tower applications the
Lc1003™ control panel is installed.
A1 ....... Lc1003™ digital controller
F10...... Fuse 10A
The fuse trips when the current from the
battery to the engine control circuit exceeds
its setting. The fuse can be reset by pushing
the button.
H16 ..... ECU warning lamp
P7........ Photocell sensitivity regulator
Is used for regulating the luminosity
sensitivity level of the photocell.
Q1 ....... General circuit breaker with ELCB or
differential protection
Interrupts the power supply when a short-
circuit occurs at the load side, or when the
earth leak detector (30 mA) or the
overcurrent protection are activated. It must
be reset manually after eliminating the
problem.
Q2-5 .... Circuit breakers for lamps
The control panel provides 4 circuit breakers
for the lamps (one for each lamp). The 4
lamps are controlled by the Lc1003™
controller, by means of relays.
S20 ..... REMOTE/ON/OFF switch
Position
: REMOTE START, for Auto
Photocell or weekly timer
start option
Position I:
ON, for manual start
Position O:
OFF, to isolate the controller
S25 ..... Auto positioning switch
Put the switch in position AUTO to activate
ASM (Auto Rise and Lower Safety Mast).
Put the switch in position MAN to de-
activate ASM.
S50 ..... UP button
Push the UP button to extend the mast.
S51 ..... DOWN button
Push the DOWN button to lower the mast.
Features of the Lc1003™ controller
The dedicated Lc1003™ controller provides unique
features and benefits for light tower application, such
as:
– Reliability/functionality: sequence 4 lighting
output
– 8 event scheduler: weekly timer
– Fuel efficiency: auto lamps shutdown
– User friendly operation
– Remote start with photocell
2.4.3
Emergency stop button
S2........Emergency stop button
Push the button to stop the light tower in case
of an emergency. When the button is
pressed, it must be unlocked by rotating it
clockwise, before the light tower can be
restarted.
S50
S51
S20
0
1
H16
Q2
Q3
Q4
Q5
Q1
Q6
P7
AUTO MAN
F10
AUTO MAN
S50
Q1
Q2-5
S20
F10
A1
S51
P7
H16
S25
S2
00_00_HiLight H6+_EN.book Page 21 Friday, June 4, 2021 11:52 AM
Summary of Contents for HiLight H6+ DC
Page 2: ...00_00_HiLight H6 _EN book Page 2 Friday June 4 2021 11 52 AM ...
Page 94: ... 94 ON ROAD UNDERCARRIAGE LED 00_00_HiLight H6 _EN book Page 94 Friday June 4 2021 11 52 AM ...
Page 96: ... 96 00_00_HiLight H6 _EN book Page 96 Friday June 4 2021 11 52 AM ...
Page 97: ... 97 Circuit diagrams 00_00_HiLight H6 _EN book Page 97 Friday June 4 2021 11 52 AM ...
Page 112: ... 112 00_00_HiLight H6 _EN book Page 112 Friday June 4 2021 11 52 AM ...
Page 115: ...00_00_HiLight H6 _EN book Page 115 Friday June 4 2021 11 52 AM ...