3.19 Programmable settings
Compressor/motor
Minimum
setting
Factory
setting
Maximum
setting
Set-point 1 and 2, Workplace Full-Feature
compressors
bar(e)
4
6.8
12.8
Indirect stop level
bar
0.1
0.3
1
Direct stop level
bar
0.3
1
1.5
Proportional band
%
6
10
15
Integration time
sec
5
6
10
Parameters
Minimum
setting
Factory
setting
Maximum
setting
Minimum stop time
sec
5
5
30
Power recovery time
sec
10
10
3600
Restart delay
sec
0
0
1200
Communication time-out
sec
10
30
60
Fan motor starts per day (air-cooled
compressors)
1
240
240
Protections
Minimum
setting
Factory
setting
Maximum
setting
Compressor element outlet temperature
(shut-down warning level)
˚C
50
110
119
Compressor element outlet temperature
(shut-down level)
˚C
111
120
120
Specific protections for Full-Feature compressors:
Instruction book
API480496
71
Summary of Contents for GA 37 VSD
Page 1: ...INSTRUCTION BOOK API480496 GA 37 VSD ...
Page 2: ......
Page 14: ...Front view GA 37 VSD up to GA 45 VSD Workplace Full Feature Instruction book 12 API480496 ...