![Atlas Copco GA 37 VSD Instruction Book Download Page 120](http://html.mh-extra.com/html/atlas-copco/ga-37-vsd/ga-37-vsd_instruction-book_3001661120.webp)
9.3
Protection settings
Settings for fan motor overload protection (Q15) (F15 for IT)
Frequency (Hz)
Voltage (V)
GA 37 VSD
Q15 (A)
UL/cUL
60
460
2.6
9.4
Dryer switches
General
The regulating and safety devices are factory-adjusted to give optimum performance of the dryer.
Do not alter the setting of any of the devices.
9.5
Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute)
bar
1
Air inlet temperature
˚C
20
Relative humidity
%
0
Working pressure
See section Compressor data.
Limits
Maximum working pressure
See section Compressor data.
Minimum working pressure
bar(e)
4
Maximum air inlet temperature
˚C
46
Minimum ambient temperature
˚C
0
Maximum altitude operation (1)
m
1000 m above sea level
Maximum altitude operation (1)
ft
3281 ft above sea level
(1): For operation at higher altitude: contact Atlas Copco