CLEANING AND INSPECTION OF THE 2nd STAGE
Rinse all plastic and silicone parts in fresh warm soapy water solution. Rinse with clean
warm water and then blow the parts dry with compressed air to remove any sand and dust
particles.
DO NOT use vinegar or other acid solutions on the plastic parts since this will cause the
plastic to become brittle!
If necessary because of deposits or corrosion, clean all metal parts of the second stage in an
ultrasonic cleaner or cleaning solution.
5.3 COMMONLY USED CLEANING SOLUTIONS
SOLUTION
COMMENTS
Hot Soapy water
Preferable. Good for plastic, silicone
and plated metal parts.
Vinegar and water
(equal part solution)
(weaker solution in Ultrasonic
Cleaner)
Ingredients easily available.
Approx. 15 min. cleaning time.
May damage chrome finish.
Never use on plastic parts.
Vinegar dissolves the plastics in most
polymers making them brittle and
more prone to breakage.
Simple Green R and Water
Simple Green is a readily available
degreaser. Read the product label for
mixing ratios with water.
Cleaning solutions recommended
by ultrasonic cleaner
manufacturers
The preferred choice. Check with the
manufacturer for strengths and
recommended uses for their cleaners.
Choose soap solutions over acidic
ones.
5.4 HANDLING TIPS
How your customers treat their regulators will directly influence the unit’s
function and durability.
Following are a few tips that you can pass on to your customers to help assure
the durability of their
PINNACLE
Scuba Regulator.
A. PRE-DIVE CHECKS:
5.4.1
Check the hoses and hose connections for cuts, abrasions or other signs
of damage before mounting the regulator on the tank valve. Slide the
hose protectors back to inspect the areas of the hose normally covered.
Be sure all hose connections are tight.
5.4.2
Summary of Contents for Splash Tech R60 2nd Stage
Page 1: ...2nd Tech R60 2nd Stage Service Manual TECH R60 2nd STAGE...
Page 14: ...Remove the DIAPHRAGM WASHER 7 and the diaphragm 6 from the housing 3...
Page 29: ...Install a new well lubricated O ring 11 onto the ADJUST KNOB 10...
Page 39: ...Re check work of breathing Replace mouthpiece with cable tie...