Depress the lever (20) fully onto the inlet tube. Grasp the tab of the Venturi Lever (23). While
pulling on the Venturi Lever (23), push the inlet tube assembly out of the housing (3).
Remove the Venturi Lever (23) from the valve tube assembly. Remove and discard the O-ring
(24) from the Venturi Lever (23).
Turn the ADJUST KNOB (10) clockwise 1/4” turn. The pin (19) will fall out of the inlet tube or
can now be easily removed.