Hold the diaphragm up to a light source. Gently stretch the diaphragm and look for tears or
pinholes. If any are found, replace the diaphragm.
Loosen and remove the nut (26) from the inlet tube (18)
Remove the plastic bushing (25) from the inlet tube.
Remove and discard the O-ring (17) from the inlet tube.
Turn the ADJUST KNOB (10) fully counterclockwise until it comes to its stop. Do not use an
unreasonable force to do this. Stop turning the plug as soon as a resistance is felt.
Summary of Contents for Splash Tech R60 2nd Stage
Page 1: ...2nd Tech R60 2nd Stage Service Manual TECH R60 2nd STAGE...
Page 14: ...Remove the DIAPHRAGM WASHER 7 and the diaphragm 6 from the housing 3...
Page 29: ...Install a new well lubricated O ring 11 onto the ADJUST KNOB 10...
Page 39: ...Re check work of breathing Replace mouthpiece with cable tie...