Rev.0 13/01/2020
Operator Panel | TURNTABLE - MAST
24
E16
Emergency intervention
-Emergency button pressed.
-Carriage door open.
-Unblock the button and restore the power
circuit.
-Close the door and restore the power circuit.
If FE or FM carriage, check the bridge on the
connector. Check the emergency microswitch.
E20
Non-volatile memory
error functions (I2C) #0
-No response from memory.
-Replace the memory I
2
C (24LC256).
E21
Non-volatile memory
error functions (I2C) #1
-Memory timeout.
-Replace the memory (24LC256).
E22
Non-volatile memory
error functions (I2C) #2
-Communication error.
-Replace the memory (24LC256).
E23
Non-volatile memory
error functions (I2C) #3
-Communication error.
-Replace the memory (24LC256).
E24
Non-volatile memory
error functions (I2C) #4
-Memory occupied.
-Replace the memory (24LC256).
E25
Non-volatile memory
error functions (I2C) #5
-Write error.
-Replace the memory (24LC256).
E26
Non-volatile memory
error hidden parameters
(EE) #1
-Periphery occupied.
-Replace the microcontroller (PIC).
E27
Non-volatile memory
error hidden parameters
(EE) #2
-Interruption during writing.
-Replace the microcontroller (PIC).
E28
Non-volatile memory
error hidden parameters
(EE) #3
-Failed check given after writing.
-Replace the microcontroller (PIC).
E29
Non-volatile memory
error hidden parameters
(EE) #4
-Timeout writing data.
-Replace the microcontroller (PIC).
E50
Error in creasing position
sensors
-Both sensors are engaged.
-Check the proper electrical wiring or proper
installation and mechanical operation.
E51
Creasing locked during
closure
-Creasing blocked on the top sensor.
-Check motor operation.
-Check electrical connection
-Make sure there are no mechanical obstacles.
-Check sensor operation
E52
Creasing block during
opening
-Creasing blocked on the bottom
sensor.
-Check motor operation.
-Check electrical connection
-Make sure there are no mechanical obstacles.
-Check sensor operation
E53
Top limit switch error: did
not engage during ascent
command (creasing)
-The carriage blocked during ascent.
-Check motor operation.
-Check operation of the top sensor and replace
if broken.
-Make sure there are no mechanical obstacles.
Summary of Contents for EVA
Page 2: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 2 ...
Page 4: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST II ...
Page 5: ...Atlanta Stretch S p A 1 1 1 1 1 1 1 Picture 1 ...
Page 6: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 2 1 1 2 Picture 2 ...
Page 7: ...Atlanta Stretch S p A 3 1 1 3 Picture 3 ...
Page 12: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 8 1 2 1 2 1 Picture 5 ...