Atlanta Stretch S.p.A.
13
NOTE
: It is also possible to order models with film consumption
expressed in metres. In this case as well, to obtain good precision,
correctly set the diameter of the measurement roller in the parameter
F24
.
Screen calibration
With the machine alarming, press any point on the screen; after 10
seconds, on displays
(P)
and
(F)
,
PASS
will appear to indicate that the
password is required.
On the display
(V)
a count from 0 to 200 will appear; continue to hold
it until a number from 90 to 99 is reached.
Passing the guard, the display
(F)
will show
Pt
and display
(V)
will show
CAL
. The display
(P)
shows 4, or the number of points to touch.
At this time, touch 4 points in sequence:
1) In the top left (tip of the finger inside the
F01
icon).
2) In the top right (top left corner of the rectangle of the
(T)
icon).
3) Bottom right (cross at the bottom right).
4) Bottom left (cross at the bottom left).
After every time the display
(P)
is touched the count goes down from 4
to 0. With the last touch, the display
(V)
will show
End
for one second if
the calibration was successful, otherwise
Err
will appear.
At the end of the process, the machine will restart by itself.
Turntable end carriage in-phase stop*
Pressing the icon
(N)
, the rotary table turns until it reaches a
predetermined position (called end-of-cycle stop).
Press icon
(I)
to lower the carriage to its bottom position and then stop
it.
Press icon
(q)
to lift the pressure roller to its top position and then stop
it.
(*)
The machine must not be in cycle; press the
RESET
icon
(E)
to exit.
Summary of Contents for EVA
Page 2: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 2 ...
Page 4: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST II ...
Page 5: ...Atlanta Stretch S p A 1 1 1 1 1 1 1 Picture 1 ...
Page 6: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 2 1 1 2 Picture 2 ...
Page 7: ...Atlanta Stretch S p A 3 1 1 3 Picture 3 ...
Page 12: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 8 1 2 1 2 1 Picture 5 ...