Specifications
Table 5.4—Master and Standard Tool Plate
Recommended Max Payload
39.6 lbs (18 kg)
The mass attached to the Tool Changer.
Static Moment (x/y)
500 lbf-in
(56.5 Nm)
Maximum recommended working load for optimum
performance of the Tool Changer
Static Torsion (z)
690 lbf-in
(78 Nm)
Maximum recommended working torque for
optimum performance of the Tool Changer
Operating Temperature Range
-4–122°F
(-20C to 50°C)
Operating temperature range.
Operating Voltage
21-30VDC
US1/US2/Latch/Unlatch
Operating Current
200mA
continuous,
3.5A peak during
locking
US2
Weight (coupled, no access.)
3.93 lbs (1.78
kg)
Weight of Master and Tool together
Master Weight
3.1 lbs (1.4 kg)
Tool Weight
0.92 lbs (.42 kg)
Max. Recommended distance
between Master and Tool plate
0.04 in.
(1.0 mm)
No-Touch locking technology allows the Master
and Tool plates to lock with separation
when coupling.
Positional Repeatability
0.0006”
(0.015 mm)
Repeatability tested at rated load at one
million cycles.
Time to Lock / Unlock
1 second
Master Side Mounting Pattern
Custom 55 mm
X
40 mm
Refer to
Tool Side Mounting Pattern
ISO 63 mm
Refer to
Number of Module Flats
3
Available Patterns:
Flat A – Motor (Master), open (Tool)
Flats B & D – J16 Style
Flat C – J16 Style, or K Series