Troubleshooting
To access the diagnosis menu press the F3 button
on the main menu.
Symptoms
Cause
Solution
Different weight result
1
Balancer is not fixed on the floor Check the anchor bolts
Incorrect calibration
Re-Calibrate the machine
Shaft not fixed
Check the fixing of the shaft
Shaft bent
Check the shaft
Piezo-Sensor not fixed of broken Check the tightness of the nuts
or replace them
Rim not clean or bent
Check the rim
Buttons not react
Keyboard not connected or
loosen connection
Check the connection
Motor / Electronic
Doesn´t brake
Brake resistor defect or not
connected
Check brake resistor or
connection
Noises from the motor
Brake resistor defect or not
connected
Check brake resistor or
connection
Main board broken
Contact ATH-Service team
The capacitor is defect or not
connected.
Check capacitor or connection
Circuit breaker activated
Main switch is not connected
correctly or there is a contact
error.
Check the connection