2.2Mechanical
Parameter
Specification
Dimensions:
19” (483 mm) wide x 7” (178 mm) high x 24” (610 mm) deep chassis
size which is available in a rack mount or stand-alone configuration.
Unit Weight:
61 lb. (28 kg)
Material:
Aluminum chassis, panels and cover.
Finish:
Light textured painted external surfaces.
Front and rear panels semi-gloss polyurethane color no. 26440
(medium gray)
Top, bottom and sides semi-gloss polyurethane color no. 26622 (light
gray).
Cooling:
Fan cooled with air intake on the sides and exhaust to the rear.
Internal
Construction:
Modular sub assemblies.
Rear Panel
Connections:
(see section 3 for description of connections)
Input terminal block with cover
Output terminal block with cover
Remote voltage sense terminal block
System interface (not for table top use, use only in rack enclosed
systems)
Clock and Lock (not for table top use, use only in rack enclosed
systems)
RS232, GPIB, USB, LAN (option)
2.3Environmental
Parameter
Specification
Operating Temp:
0 to +40
°
C.
Storage Temp:
-40 to +85
°
C.
Altitude:
< 2000 m
Relative Humidity:
80% maximum for temperatures up to 31
°
C decreasing linearly to
50% at 40
°
C.
Installation/Over voltage
Category:
ΙΙ
Pollution Degree:
2
Indoor Use Only
Vibration:
Designed to meet NSTA 1A transportation levels.
Shock:
Designed to meet NSTA 1A transportation levels.
30
i Series II / NSG 1007 II / iM Series II
Summary of Contents for 10002iX
Page 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Page 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Page 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Page 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Page 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...