User Manual
California Instruments
Output Parameter
i / iM Series
NSG 1007
5001, 15003i/iX
10001i/iX
1NSG 1007-5
5000 VA AC, 3500 W DC
10000 VA AC, 7000 W DC
15000 VA AC, 10500 W DC
5000 VA AC, 3500 W DC
10000 VA AC, 7000 W DC
15000 VA AC, 10500 W DC
Current, maximum amps per phase:
NSG 1007-3
22.2 Arms @ 135 VAC in 150 Vrange
11.1 Arms @ 270 VAC in 300 Vrange
15.5 Adc @ 135 VDC in 200 Vrange
7.77 Adc @ 270 VDC in 400 Vrange
5001 /15003i/iX
per phase
37.0 Arms @ 135 VAC in 150 Vrange
18.5 Arms @ 270 VAC in 300 Vrange
25.9 Adc @ 135 VDC in 200 Vrange
12.95 Adc @ 270 VDC in 400 Vrange
10001i/iX
74.0 Arms @ 135 VAC in 150 Vrange
37.0 Arms @ 270 VAC in 300 Vrange
51.8 Adc @ 135 VDC in 200 Vrange
25.9 Adc @ 270 VDC in 400 Vrange
10001i/iX
111 Arms @ 135 VAC in 150 Vrange
55.5 Arms @ 270 VAC in 300 Vrange
77.7 Adc @ 135 VDC in 200 Vrange
38.8 Adc @ 270 VDC in 400 Vrange
Current derates at higher voltage settings along constant power curve. See Figures Figure 2-1 through
Figure 2-8 for voltage current ratings per phase or output by model.
Maximum current for which specifications apply is derated linearly from 50% of voltage to 10% of
specified current at 5% of voltage range as shown. Higher currents are available but not all specification
will apply under these conditions.
Note: For the NSG 1007, the current output in the AC & DC mode is equal to the current in the AC
mode if the DC voltage is less than 20% of the full scale voltage. It is equal to the DC current for DC
voltages more than 20% of full scale
NSG 1007 Series II
21
Summary of Contents for 10002iX
Page 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Page 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Page 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Page 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Page 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...