10-18
Issue 2 April 1996
Alarms
Change Alarm Forwarding
Procedure 2:
Change
alarm path
Start on the Change Alarm Path screen.
3
Select
proxy-agent
.
4
Enter
change alarm-path
.
Result: The Change Alarm Path screen displays.
5
Go to Procedure 2: Change alarm path.
Step
Action
Step
Action
1
Complete the Receive From field and any required
subfields.
Hint: Press
Ctrl-y
for a list of valid values. If you need to
enter the name of the tty device, use the following
format: ttyxx.
2
Complete the Forward To field and any required
subfields.
Hint: This field only displays if you enter “Trouble
Tracker” in step 1.
3
Press
Ctrl-e
to save your work.
4
Enter
start -proxy
at the Proxy Agent Menu.
Result: The Proxy Agent builds the required directories
and files for forwarding the alarm to the destination you
chose in step 2.
End
Summary of Contents for OneVision DEFINITY G3 Guide
Page 11: ...Contents xii Issue 2 April 1996 GL Glossary GL 1 IN Index IN 1...
Page 78: ...4 18 Issue 2 April 1996 UnixWare Administration To Back Up and Restore...
Page 114: ...5 36 Issue 2 April 1996 Planning Connectivity Alarm Path 5 Proxy Agent PC...
Page 124: ...6 10 Issue 2 April 1996 Connectivity Digital Connections 5 Data module or ADU 6 Proxy Agent PC...
Page 172: ...7 24 Issue 2 April 1996 Serial I O Cards To Create Port Monitor Entries...
Page 235: ...A 4 Issue 2 April 1996 PA001 Form PA001 Administration Request Form...
Page 237: ...A 6 Issue 2 April 1996 PA001 Form PA001 Administration Request Form...
Page 243: ...Issue 2 January 1996 B 5 Design Configuration Analog On Network...
Page 245: ...Issue 2 January 1996 B 7 Design Configuration Analog On Network...
Page 247: ...Issue 2 January 1996 B 9 Design Configuration Other On Network...
Page 250: ...B 12 Issue 2 January 1996 Design Configuration Customer Provided Multiplexor Data Networks...
Page 253: ...Issue 2 January 1996 B 15 Design Configuration Customer Provided Multiplexor Data Networks...
Page 259: ...Issue 2 January 1996 B 21 Design Configuration Local Connection 5000 or Less G3rV1 V2 V3...
Page 262: ...B 24 Issue 2 January 1996 Design Configuration Remote Connection G3rV1 V2 V3...