![AT&T 4 ESS Manual Download Page 246](http://html1.mh-extra.com/html/atandt/4-ess/4-ess_manual_2994836246.webp)
Defective
oscillator
removed
CLOCK
CHAIN
OSCILLATOR
LOCATION
0
1
2
3
TABLE B
033-21
033-56
133-21
133-56
Oscillator
power
removed
AND
AND
PWR OFF
P21
and
POWER P18
and
P19
connectors
[14] Disconnect
FREQ CONTROL INPUT
[15] Disconnect
D/A INPUT/OUTPUT
connector
J20
[16] Remove eight screws holding oscillator
[17] See WARNING 1. Remove oscillator
[13] Disconnect ground strap from
oscillator to frame upright
from network clock frame
mounting plate to frame
REMOVE 39B OSCILLATOR
remove power
ROS/OFF
switch is
in
ROS
position
At oscillator
being removed [TABLE B]
oscillator being removed:
[10] Depress
ROS/OFF
switch to
[12] Disconnect
RF OUTPUT
connector
P13
[11] 24V fuse for oscillator
See TABLE A. At switch location associated with
[9] Ensure chain OOS;
OS
and
OFF NORM
lamps lighted
lamp
lights
CLOCK
CHAIN
POWER SWITCH
FRAME LOCATION
0
1
2
3
066-03
066-68
166-03
166-68
FUSE LOCATION
BAY
HMP
0
0
1
1
07
07
07
07
TABLE A
FUSES
0B0A
0B0B
1B0A
1B0B
39B oscillator is
fragile item.
Defective units
are repairable
location only
at repair
SD-4A014-02
WARNING 1
DLP
234-151-013
DEC 1995
537
Issue 8