adjust potentiometer
to measure 0.92V
waveform be
adjusted to 0.92V
peak-to-peak
probe from
Yes
No
terminal 201
peak-to-peak and
replace level
adjustment cover
and repeat from
of
FB687
pack
level adjustment cover
present
No
Yes
waveform
oscillator output
cable problem
Yes
waveform
present
touch it to center
No
from terminal 201
pin of oscillator
output jack
of
FB687
pack and
connector
P13
RF OUTPUT
CLEAR PHASE ERROR — DISCIPLINED RUBIDIUM OSCILLATORS
[106] Is
[111] Remove oscillator
[112] Can
[113] Remove
[107] Remove
DRO oscillator
[108] Remove probe
[109] Is
[110] Correct
using SD-4A036-01
and repeat from
Page 9
TAP
234-151-013
Issue 8
DEC 1995
PAGE 12 of 19