![AT&T 4 ESS Manual Download Page 165](http://html1.mh-extra.com/html/atandt/4-ess/4-ess_manual_2994836165.webp)
TEST MISMATCH SUPPLEMENTARY DATA
ROUTINE CALLED
FAILING TEST
IN LAST SUB-
ADDRESS OF
NUMBER OF SUPPLEMENTARY DATA WORDS
THAT PRECEDE DOLOOP DATA WORDS
NUMBER OF DOLOOP DATA WORDS THAT
PRECEDE SUBROUTINE DATA WORDS
NUMBER OF SUBROUTINES CALLED THAT
BOUND THE FAILING TEST
FIFTH DATA WORD
LAST DATA WORD PRINTED
01510001 00000002 00000001 00000244 00000533
ADDRESS IN PHASE
WHERE FIRST
SUBROUTINE CALLED
ADDRESS IN FIRST SUBROUTINE
000244
SECOND SUBROUTINE FIRST SUBROUTINE
000533
CALLSUB(PUDGWXYZ)
CALLSUB(PUDGABCD)
LISTING (PUDGABCD) LISTING (PUDGWXYZ) PHASE LISING
SUBROUTINE NAME
DETERMINE LOCATION AND FUNCTION OF SUBROUTINES CALLED
28360 02000000 75777757 00000000 01000240 00000053
12200002
DGN: SCLK 0 CONTR 0 PH 2 STF-BOF (16,00000000 00000000)
SUBROUTINE DATA WORDS
*
*
SUBROUTINE DATA WORDS THAT PRECEDE THE LAST ONE PRINTED
WHERE SECOND SUBROUTINE CALLED
ARE FOR THE 2ND, 3RD, ETC SUBROUTINES CALLED (RIGHT TO LEFT)
FAILING TEST
EXPECTED RESULTS
(EXPR) DATA
000053
Figure 1 — Relationship of Subroutine Data Words to Phase and Subroutine Listings
DLP
PAGE 2 of 3
234-151-013
501
Issue 8
DEC 1995