GB 18
installation
general
When the appliance is not fitted with a power cord with plug,
the appliance may only be connected by a qualified electician.
please note:
The correct voltage for the appliance and the connection value
are shown on the rating plate at the back of the oven. Always
comply with local regulations when connecting the appliance.
U.K. only
To connect the appliance a fixed connection has to be made.
The wire which is coloured green and yellow must be
connected to the terminal which is marked by the letter E or
the earth symbol
or which is coloured green, or green
and yellow. The wire which is coloured blue must be
connected to the terminal which is marked by the letter N or
which is coloured black. The wire which is coloured brown
must be connected to the terminal which is marked by the
letter L or which is coloured red. If the input of the appliance
acceeds 3 kW, the appliance has to be connected to an outlet
with a rated current exceeding 13 Amp.
electrical connection
230 V -50 Hz. Nominal power 3 kW.
Make sure the appliance has an earth wire connection. Use
good quality cable for connecting, e.g. H05RRF, 1,5 or
2,5 mm
2
, with 3 or 5 cores, depending upon the regulations.
With following colour code:
brown =
phase L
blue =
phase N
green/yellow =
earth (
)
black =
neutral or phase
Depending upon the wiring diagram, you can use the black
cores for neutral or a phase. The cable must have a plug
suitable for a nominal load of at least 15 A. If you want to
make a fixed connection, ensure that a multi-pole switch with
a distance between contacts of 3 mm is installed in the
supply cable.
88015916_HL_OX6093R 09-03-2004 13:59 Pagina GB 18