installation
electrical connection
GB 32
general
For the connection, use an approved cable, in accordance
with the regulations. The cable must bear one of the
following indications:
H05V2V2-F, H05RR-F or H05RN-F.
There is a label on the underside of the appliance with the
wiring diagrams. The connection terminals are accessible
once you have opened the junction box on the underneath.
The junction box cover can be opened with a screwdriver.
If you want to make a fixed connection, make sure that a
multi-polar switch with a contact separation of at least 3 mm
is fitted in the supply line.
1
2
3
4
5
right zones
left zones
Type of hob
Induction
Component voltage
230V 50Hz
Appliance width x depth
774 X 522 mm
Installation height from
top of worktop
48 mm
Cut out dimensions width x depth 750 x 490 mm
Capacities of modules
Left
3600 W
Right
3600 W
700001870100 HL HI7071M.qxp 12-10-2005 12:00 Pagina GB 32