Voltage between line conductors must be 220–240 V~.
2 phase conductors (220–240 V~, 50-60 Hz)
L1
= black/brown
L2
= blue
= yellow-green
For appliance types: BI1CA…, BI6CA…, BI6CB…, BI7CA…, BI8CA…, BI8CB…, BI9CE…
NOTE!
Note: The appliance type can be found on the rating plate on the bottom of the appliance.
Voltage between lines must be 220–240 V~. Power cord core cross sectional area should be at least
as listed in Table for the following current limiter settings which should be adjusted to your circuit
breakers:
Number and cross section
of Power cord wires
Power cord
type
Connection type
Current limiter
settings
4x1,5 mm²
H05VV-F
3 phase conductors
2x16A
4x1,5 mm²
H05VV-F
3 phase conductors
2x13A
4x1,5 mm²
H05VV-F
3 phase conductors
2x10A
4x1,5 mm²
H05VV-F
3 phase conductors
2x06A
3x4,0 mm²
H05VV-F
2 phase conductors
1x32A
3x4,0 mm²
H05VV-F
2 phase conductors
1x25A
3x4,0 mm²
H05VV-F
2 phase conductors
1x20A
3x4,0 mm²
H05VV-F
2 phase conductors
1x16A
3x4,0 mm²
H05VV-F
2 phase conductors
1x13A
3x4,0 mm²
H05VV-F
2 phase conductors
1x10A
3x4,0 mm²
H05VV-F
2 phase conductors
1x06A
The following connections are possible.
2 phases (220–240 V~, 50-60 Hz)
To reach the rated maximum power a fuses of 32A is needed.
Install a jumper between terminals 1 and 2 and between terminals 4
and 5.
57
Electrical installation