4-10
Operation
Control Panel
The Control Panel is divided into three functional areas:
•
Download Program Controls
•
Motion Controls
•
Dispensing Status/Safety Interlock Controls
The following tables describe each Control Panel function.
Table 4-3 Download Program Control Functions
Button/Indicator
Function
ABORT
Abort
halts a production run. After you press the
Abort
button,
its red LED lights to indicate that the currently loaded program is
discontinued. After a program is aborted you must press
Reset
,
then
Find
Home
before you can restart the program.
PAUSE
Pause
temporarily stops a production run. When its yellow LED
indicator is ON, the system is paused. You can pause a
production run at any time. To resume dispensing, press
Pause
again. When the LED indicator turns OFF, the system resumes
dispensing.
PROGRAM
0
1
2
3
4
5
6
7
8
9
START
Download Program Controls. The LED indicators numbered
from
0
to
9
indicate dispensing programs that you can save in
the dispensing system memory. Use the up/down arrows to
select the desired dispensing program. Press the Program
Start
button to run the selected program.