Startup/Shutdown
5-5
?
NOTE
You should perform a
Valve Offsets
routine before beginning a production run. If you
change the needle during a production run, you need to perform only the shorter
Find
Needle XYZ
procedure to continue dispensing.
Scripted Valve Offsets
The
Scripted Valve Offsets
procedure allows you to customize machine offsets routines to suit your
specific application and system configuration, reducing setup time. You can use one of the machine setup
scripts included with FmNT, or create a custom script file (see the
Setup Scripts Options
in FmNT for
more information on developing your own script). A customized script allows you to rerun previous steps
without starting from the beginning, and to exit the routine at any point. Prompted setup scripts can be
designed for each fluid pump type used in your application, or for dual-action dispensing. See the
Fluidmove for Windows User Guide
and
Scripted Prompted Setup
in FmNT Online Help for further
information.
To perform Scripted Valve Offsets:
1.
In the FmNT Main Window, click on
Configuration
.
2.
Choose
Machine Offsets
.
3.
Select
Scripted Valve Offsets
from the cascading menu.
>
If
Scripted
Valve Offsets
is not available, select
Machine Offsets Parameters
and activate
Scripted
Valve Offsets
in the
Machine Offsets Parameters
dialog box. Click on
OK
.
4.
Return to
Configuration
.
5.
Choose
Machine Offsets
.
6.
Select
Scripted Valve Offsets
from the cascading menu.
7.
In the
Machine Setup
dialog box, click on
Run to End
, or step through each machine offsets
procedure appropriate to your application.
8.
Follow the on-screen prompts to complete the setup routine.
9.
If your system is configured for dual-action fluid dispensing, repeat the above procedures for
Valve 2.
>
Consult the
Fluidmove for Windows NT User Guide
or Online Help for assistance.
Camera-Assisted Scripted Valve Offsets
Camera-Assisted Scripted Valve Offsets
routines were developed to improve operator safety by using
the camera to verify accuracy of needle position when calculating machine offsets. Previous offset
routines including
Calculate Master Offsets
,
Valve Offsets
, and
Scripted Valve Offsets
required the
user to confirm the accuracy of needle placement from within the work area, increasing the risk of
mechanical injury or burns. The CASVO routine, updated from
Scripted Valve Offsets
procedures, uses
the camera to position the needle for faster, safer calculation of machine offsets.
Summary of Contents for Century C-721 Series
Page 2: ...Revision History Revision Date Description Pages Affected A 5 01 Initial Release All ...
Page 8: ......
Page 12: ......
Page 36: ......
Page 76: ......
Page 108: ......
Page 114: ......
Page 117: ...Needle Heater 12 3 Figure 12 2 HT 06 Figure 12 3 HT 10N ...
Page 122: ......
Page 138: ......