Heaters
15-7
Heater Setup
There are no hardware setup procedures required for the heaters. The heaters are installed at the Asymtek
factory prior to shipping and configured in FmNT according to your specific requirements.
For general operation, it helps to know how your system heaters are configured. The following
information is for reference and troubleshooting only.
Contact and Impingement Heater Configuration
Contact and impingement heaters are divided into zones capable of closed-loop, independent temperature
regulation. Within FmNT, each zone is configured as a single closed-loop system. Figure 15-5 shows a
Century Series dispensing system with contact heaters in all three dispensing zones. Your system may
have heaters in one, two or three zones (third heat station optional).
Item
Description
1
Loop 1
2
Loop 2
3
Loop 3
4
Pre-Dispense Zone
5
Dispense-Heat Zone
6
Post-Dispense Zone
Figure 15-5 Contact Heater Configuration