Description

 

Top loading bottled water cooler unit with hot and cold dispensers. Includes non-refrigerated storage, perfect for storing cups or other supplies. Com-

pressor refrigeration: high efficiency aluminum coil compressor is used for cooling. Electric heating: high power stainless steel hot water tank is designed 

for heating. Water source is bottled water.

Ratings

•  Dimensions: 310mm×360mm×1000mm (12”×14”×39”)
•  Total Power: 540W
•  Heating Power: 420W
•  Cooling Power: 120W

• 

Feed Water Type: Bottled Water

• 

Voltage/Frequency: 220-240V/50-60Hz

• 

Water Heating Capacity: 1GPH / 4LPH

• 

Water Cooling Capacity: 0.5GPH / 2LPH

DANGER

 

– Indicates death or serious injury will result if proper precautions are not taken.

WARNING

 – Indicates death, serious injury or property damage can result if proper precautions are not taken.

CAUTION

 – Indicates some injury or property damage may result if proper precautions are not taken.

Definitions

Authorized Service Personnel

 – Factory trained personnel or personnel having working knowledge of electrical, 

plumbing and machine (appliance) maintenance procedures.

Safety

DANGER

WARNING

• 

Prior to use, this dispenser must be properly assembled and installed in accordance with this manual.

• 

This dispenser is intended for water dispensing only. Do NOT use other liquids. Do NOT use for other purposes. Never use any other liquid in the 

dispenser other than known and microbiologically safe bottled water.

CAUTION

• 

For indoor use only. Keep water dispenser in a dry place away from direct sunlight. Do NOT use outdoors.

• 

Install and use only on a hard, flat and leveled surface.

• 

Do NOT place dispenser into an enclosed space or cabinet.

• 

Do NOT operate dispenser in the presence of explosive fumes.

• 

Position the back of the dispenser no closer than 4 inches from the wall, permitting free airflow between the wall and the dispenser. There must be at 

least 4 inches clearance on the sides of the dispenser to permit airflow.

• 

Only use properly grounded outlets.

• 

Do NOT use an extension cord with your water dispenser.

• 

Always grasp the plug and pull it straight out from the outlet. Never unplug by pulling on the power cord.

• 

Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and safety precautions 

in this manual can result in serious injury or death.

• 

After installation, keep these instructions in a safe location for future reference. 

• 

Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate. 

• 

Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection.

• 

A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to allow electrical 

disconnection of the unit from electrical supply after installation.

Installation / Care / Use Manual

Original Instructions

Model: DSBWCT5G

Summary of Contents for DSBWCT5G

Page 1: ...liquid in the dispenser other than known and microbiologically safe bottled water CAUTION For indoor use only Keep water dispenser in a dry place away from direct sunlight Do NOT use outdoors Install and use only on a hard flat and leveled surface Do NOT place dispenser into an enclosed space or cabinet Do NOT operate dispenser in the presence of explosive fumes Position the back of the dispenser ...

Page 2: ...rvice personnel Disconnect electrical supply serving the Installation area to reduce risk of electrocution Unit not suitable for installations where water jets could be used DANGER Ensure proper ventilation by maintaining clearance between condenser and wall Never wire compressor directly to electrical supply Warranty is void if Installation is not made in accordance with current Manufacturer s in...

Page 3: ...long time turn off the heating switch of the refrigeration switch to save power 6 In case the machine is not needed for a long time remove the plug turn off the copper chrome plated ball valve and drain off the remaining water through the outlet For another use discharge water for 3 5 min 7 In the event that the machine is blocked by ice due to environmental conditions below freezing point keep th...

Page 4: ...iscretion reserves the right to deny the warranty if i technical intervention was realized by unauthorized personnel ii any seals on the product were broken or serial numbers on the product were modified ii there was any alteration or falsification of the information provided in this warranty and or the Installation Care Use Manual iii the terms of the warranty period expired iv the product was us...

Page 5: ...ن قبل من اإلصالح محاولة 1 حالة في الضمان إلغاء في بالحق لها يحلو حسبما إلكاي شركة تحتفظ الضمان إلغاء التركيب كتيب أو و الضمان هذا في الواردة للمعلومات تزييف أو تغيير أي وجود 2 المنتج على التسلسلية األرقام تعديل أو المنتج على موجودة أختام المنتج هذا مع الشرب مياه بخالف شيء أي استخدام أو و 5 المكشوفة األماكن في المنتج استخدام 4 الضمان مدة انتهاء 3 االستخدام الرعاية االستبدال أو التصليح عالج ذلك من و...

Page 6: ...الكروي الصمام وإطفاء القابس إزالة برجاء طويلة زمنية لفترة للماكينة الحاجة عدم حالة في دقائق 5 3 لمدة المياه بتفريغ قم 7 7 بتشغيله قم ثم ساعات 4 لمدة اإلغالق وضع في التبريد مفتاح وجود على حافظ التجميد نقطة عن الحرارة درجة فيها تقل التي البيئية الظروف بسبب بالثلج الماكينة انسداد حالة في العملية الستمرار 8 8 المحلية الجهات من مطلوب كان إذا GFCI األرضي العطل تيار لقاطع حماية الكهرباء إمداد مصدر استخدا...

Page 7: ... أن يجب الكهربائي الصعق خطورة لتقليل التركيب منطقة يخدم الذي بالكهرباء اإلمداد مصدر افصل المياه نفاثات استخدام فيها يمكن التي للتركيبات مناسبة الوحدة تكون ال خطر الجدار و المكثف بين مسافة بترك المناسبة التهوية من التأكد عليك الكهربائي بالتيار ا ً ر مباش المكبس بتوصيل تقم ال ع ِ ن ص ُ م ال لتعليمات ًا ق وف التركيب عدم حالة في الغي الضمان يعتبر 3 الشكل راجع صليبي مفك باستخدام القاعدة للوح الخلفي للج...

Page 8: ...مست سطح على فقط واالستخدام التركيب يتم مطوقة خزانة أو مكان في المبرد وضع يجب ال متفجرة أدخنة وجود في المبرد تشغيل يجب ال جوانب على األقل على بوصة 4 قدرها مسافة وجود من البد والمبرد الجدار بين الهواء تدفق بحرية للسماح بوصة 4 عن تقل ال الجدار من مسافة على للمبرد الخلفي الجزء وضع يجب الهواء بتدفق للسماح المبرد مناسبة بصورة فقط باألرض الموصولة المخارج استخدام يجب المياه مبرد مع امتداد سلك استخدام يجب ...

Reviews: