5-26
Chapter 5: BIOS setup
PCI Express GEN2 Device Register Settings
In device Functions that
support Completion Timeout
programmability, allows
system software to modify
the Completion Timout value.
‘Default’ 50us to 50ms.
If ‘Shorter’ is selected,
software will use shorter
timeout ranges supported
by hardware.If ‘Longer’ is
selected, software will use.
PCI Express GEN2 Device Register Settings
Completion Timeout
[Default]
ARI Forwarding
[Disabled]
Atomic0p Requester Enable
[Disabled]
Atomic0p Egress Blocking
[Disabled]
ID0 Request Enable
[Disabled]
ID0 Completion Enable
[Disabled]
LTR Mechanism Enable
[Disabled]
End-End TLP Prefix Blocking
[Disabled]
PCI Express GEN2 Link Register
Target Link Speed
[Auto]
Clock Power Management
[Disabled]
Compliance SOS
[Disabled]
Hardware Autonomous Width
[Enabled]
Hardware Autonomous Speed
[Enabled]
→←:
Select Screen
↑↓:
Select Item
Enter: Select Item
+/-: Change Opt.
F1: General Help
F2: Previous Values
F5: Optimized Defaults
F10: Save & Exit
ESC: Exit
Completion Timeout [Default]
In device Functions that support Completion Timeout programmability, allows
system software to modify the Completion Timout value. ‘Default’ 50us to 50ms.
If ‘Shorter’ is selected, software will use shorter timeout ranges supported by
hardware.If ‘Longer’ is selected, software will use.
Configuration options: [Default] [Shorter] [Longer] [Disabled]
ARI Forwarding [Disabled]
If supported by hardware and set to ‘Enabled’, the Downstream Port disables
its traditional Device Number field being 0 enforcement when turning a Type 1
Configuration Request into a Type 0 Configuration Request, permitting access to
Extended Functions in ab ART Device immediately below the port.
Configuration options: [Disabled] [Enabled]
Atomic0p Requester Enable [Disabled]
If supported by hardware and set to ‘Enabled’, this function initistes Atomc0p
Requests only if Bus Master Enable bit is in the Command Register set.
Configuration options: [Disabled] [Enabled]
Atomic0p Egress Blocking [Disabled]
If supported by hardware and set to ‘Enabled’, outbound Atomic0p Requests via
Egress Ports will be blocked. Configuration options: [Disabled] [Enabled]
ID0 Request Enable [Disabled]
If supported by hardware and set to ‘Enabled’, this permits setting the number of
ID-Based Ordering (ID0) bit (Attribute [2]) requests to be initiated. Configuration
options: [Disabled] [Enabled]
Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.
Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Advanced
Summary of Contents for RS700-E7/RS8
Page 1: ...1U Rackmount Server RS700 E7 RS8 User Guide ...
Page 10: ... ...
Page 50: ...4 2 Chapter 4 Motherboard information 4 1 Motherboard layouts ...
Page 64: ...4 16 Chapter 4 Motherboard information ...
Page 154: ...6 40 Chapter 6 RAID configuration ...
Page 188: ...A 2 Appendix A Reference information Z9PP D24 block diagram ...