6-16
Chapter 6: RAID configuration
6.2.4
Rebuilding failed drives
You can manually rebuild failed hard disk drives using the
Rebuild
command in the
Management Menu
.
To rebuild a failed hard disk drive
1. From the
Management Menu
, select
Rebuild
, and then press <Enter>.
2. The
PHYSICAL DRIVES SELECTION MENU
displays the available drives
connected to the SATA ports. Select the drive you want to rebuild, and then
press <Space>.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Rebuild PD(s)
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A
REBUILD - PHYSICAL DRIVES SELECTION MENU
PORT #
ONLIN A00-00
FAIL A00-01
0
1
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
Summary of Contents for RS700-E7/RS8
Page 1: ...1U Rackmount Server RS700 E7 RS8 User Guide ...
Page 10: ... ...
Page 50: ...4 2 Chapter 4 Motherboard information 4 1 Motherboard layouts ...
Page 64: ...4 16 Chapter 4 Motherboard information ...
Page 154: ...6 40 Chapter 6 RAID configuration ...
Page 188: ...A 2 Appendix A Reference information Z9PP D24 block diagram ...