![Astria Fireplaces Odyssey36ZNM Installation And Operation Instructions Manual Download Page 7](http://html.mh-extra.com/html/astria-fireplaces/odyssey36znm/odyssey36znm_installation-and-operation-instructions-manual_2990906007.webp)
Astria.US.com
126797-01F
7
Screw
Rear Hole
Top View of Rod Layout
Rod
Front Hole
Ring
Screen
Identifi cation
Label Location
INSTALLATION
Continued
NOTICE: If your installation does not meet the minimum
clearances shown, you must do one of the following:
• raise the mantel to an acceptable height
• remove the mantel
BUILT-IN FIREPLACE INSTALLATION
1. Frame in rough opening. The fi replace framing must be con-
structed of steel stud material. Steel studs are provided and are
permanently fi xed amount the perimeter of the unit. Use dimen-
sions in Table 1 and rough opening layout in
Figure 4a
. Adjust
framing so that fi replace is fl ush with fi nished wall surface. If
installing in a corner, use dimensions in
Figures 4b and 4c
for
rough opening.
2. Install gas piping to fi replace location
(see Connecting to Gas
Supply,
Page 9
).
3. Carefully set fi replace in front of rough opening with back of
fi replace inside wall opening.
4. Carefully insert fi replace into rough opening.
Figure 4 - Rough Opening for Installing in Wall
Depth
(Minimum)
Width
(Inside to Inside)
Height
Figure 4a
45°
TOP VIEW
37
"
(940 mm)
44
"
(1118 mm)
FOR 36
"
MODELS
74
"
(1880 mm)
52
"
(1321 mm)
Figure 4b
45°
TOP VIEW
51
"
(1296 mm)
43
"
(1093 mm)
86
"
(2185 mm)
61
"
(1550 mm)
FOR 42
"
MODELS
Figure 4c
Figure 5 - Installing Firebox
INSTALLING DRAIN PAN DP36/DP42
The fi replace enclosure must allow for adequate drainage and fresh
air ventilation. It is recommended that a sealed, corrosion resistant
catch pan with provision for drainage be installed under fi replace
within fi replace enclosure
(see Accessories,
Page 24
)
.
INSTALLING FIREPLACE SCREEN
1. Insert each rod through all rings located at top of screen.
2. Insert fi rst rod into rear hole in left side of fi replace. Fasten rod to
rear hole near center of fi replace using #10 x 3/8" Phillips screw
provided
(see
Figure 6
).
3. Insert other rod into front hole on right side of fi replace and fasten
using remaining Phillips screw.
Figure 6 - Installing Fireplace Screen
Table 1
Rough Opening Dimensions for Built-in Installation
Model
Front Width
(Inside to Inside)
Height
Depth (Min.)
36"
44" (1118 mm)
42
3
/
4
" (1086 mm)
21" (534 mm)
42"
51" (1296 mm)
46
1
/
2
" (1182 mm)
23" (585 mm)
12" (305 mm)min.
noncombustible
wall board or
facing material
above fi replace.
Combustible
materials not allowed
adjacent to fi replace.
12" (305 mm) min.
noncombustible
wall board or facing
materials on sides.
Steel Stud or Steel