4
LOCAL CODES
Install and use fi replace with care. Follow all local codes. In the ab-
sence of local codes, use the latest edition of The National Fuel Gas
Code ANSI Z223.1/NFPA 54*; National Fuel Gas Code; Natural Gas
and Propane Installation Code, CSA B149.1; or Propane Storage and
Handling Code, CSA B149.2, as applicable.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street, 4th fl oor
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02169-7471
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of
Massachusetts if the following additional requirements are met:
•
Un-vented Room Heaters shall be installed in accordance with
527 CMR 30.
•
Installation and repair must be done by a plumber or gas fi tter
licensed in the Commonwealth of Massachusetts.
•
The fl exible gas line connector used shall not exceed 36 inches
(92 centimeters) in length.
•
The individual manual shut-off must be a T-handle type valve.
•
Unvented appliances may NOT be installed in bedrooms or
bathrooms.
•
A working smoke detector must be installed in the area where
vent-free appliances are installed.
Seller of unvented propane or natural gas-fi red supplemental room
heaters shall provide to each purchaser a copy of 527 CMR 30 upon
sale of the unit.
PRODUCT FEATURES
REFRACTORY BRICK LINER
Your fi replace features a concrete refractory brick liner. As with all
concrete liners, this liner may develop slight cracks when exposed
to heat. These cracks will not affect the performance of the fi replace.
LOCATING FIREPLACE
PLANNING
Plan where you will install the fi replace. This will save time and money
later when you install the fi replace. Before installation, consider the
following:
1. Where the fi replace will be located. Allow for wall and ceiling
clearances
(see Installation Clearances,
Page 6
).
2. Everything needed to complete installation.
3. These models are for outdoor use only.
4. Proper air for combustion and ventilation.