![Astria Fireplaces Odyssey36ZNM Installation And Operation Instructions Manual Download Page 15](http://html.mh-extra.com/html/astria-fireplaces/odyssey36znm/odyssey36znm_installation-and-operation-instructions-manual_2990906015.webp)
Astria.US.com
126797-01F
15
SPECIFICATIONS
Odyssey36ZNM
• Rating (Variable): 28,000/41,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (inches of water):
Max. 10.5" W.C., Min. 5.0" W.C.*
• Air Shutter: 3/16 OPEN
Odyssey36ZPM
• Rating (Variable): 32,000/41,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (inches of water):
Max. 14" W.C., Min. 11" W.C.*
• Air Shutter: FULLY OPEN
Odyssey42ZNM
• Rating (Variable): 32,000/47,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (inches of water):
Max. 10.5" W.C., Min. 5.0" W.C.*
• Air Shutter: 3/16 OPEN
Odyssey42ZPM
• Rating (Variable): 35,000/45,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (inches of water):
Max. 14" W.C., Min. 11" W.C.*
• Air Shutter: FULLY OPEN
*For purpose of input adjustment
HEAT LIMIT SWITCH
TO PILOT
SUPPLY
MAIN GAS
INCOMING
CONTROL
VALVE
TPTH
TP
TH
OPTIONAL
ON/OFF
SWITCH
OPTIONAL
RECEIVER
REMOTER
WHITE
BLACK
BLACK
ELECTRICAL WIRE CONNECTION WILL
REQUIRE MALE TO MALE CONNECTORS
WIRING DIAGRAM
WARNING: Fireplace must be operated only with doors fully open.