SAFETY

  Continued

Children and adults should be alerted to the hazards 

of high surface temperatures and should stay away to 

avoid burns or clothing ignition. Appliance will remain 

hot for a time after shutdown. Allow surfaces to cool 

before touching.

Carefully supervise young children when they are 

in the room with fireplace. When using the remote 

control, keep selector switch in the OFF position to 

prevent children from turning on burners with remote.

Keep the appliance area clear and free from combus-

tible materials, gasoline and other flammable vapors 

and liquids.

The finish of the front face is protected with a self 

adhering plastic coating that must be removed before 

fireplace is operated. To prevent melting, ensure that 

the plastic coating protecting the finish is removed.

 WARNING: Young children should be carefully su-

pervised when they are in the area of the appliance. 

Toddlers, young children and others may be susceptible 

to accidental burns. A physical barrier is recommended 

if there are at-risk individuals in the house. To restrict 

access to a fireplace or stove, install an adjustable safety 

gate to keep toddlers, young children and other at-risk 

individuals out of the room and away from hot surfaces.

2.  Do not place propane/LP supply tank(s) inside any structure. 

Locate propane/LP supply tank(s) outdoors (propane/LP units 

only).

3.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use any phone in your 

building

• leave the building immediately

• immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier’s instructions

• if you cannot reach your gas supplier, call the fire department

4.  This fireplace shall be used only outdoors in a well ventilated space and 

shall not be used in a building, garage or any other enclosed area.

5.  Do not use this fireplace as a wood-burning fireplace. Use only 

high temperature pebbles that are approved for use with this 

fireplace. 

6.  To prevent the creation of soot, follow the instructions in Cleaning 

and Maintenance, Page 16.

7.  Before using furniture polish, wax, carpet cleaner or similar products, 

turn fireplace off. If heated, the vapors from these products may cre-

ate a white powder residue within burner box or on adjacent walls or 

furniture.

8.  Do not run fireplace

• where flammable liquids or vapors are used or stored

• under dusty conditions

9.  Do not use this fireplace to cook food or burn paper or other 

objects.

10. Do not use this appliance if any part has been under water. Immedi-

ately call a qualified service technician to inspect the appliance and 

to replace any part of the control system and any gas control that 

has been under water.

11. Turn fireplace off and let cool before servicing. Only a qualified 

service person should service and repair fireplace.

12. To prevent performance problems in propane/LP units, do not use 

propane/LP fuel tanks of less than 100 lbs. capacity (propane/LP 

units only).

13. Provide adequate clearances around air openings.

14. Solid fuels shall not be burned in this appliance.

Installation and repair should be done by a qualified 

service person. The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required as 

necessary. It is imperative that the control compart-

ment, burners, and circulating air passageways of the 

appliance are kept clean.

1.  WARNING: This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not convertible 

for use with other gases. 

Summary of Contents for BerlinLights43ZEN

Page 1: ...the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier D...

Page 2: ...e you to chemi calsincludingCarbonBlack whichisknowntotheState of California to cause cancer and Carbon Monoxide which is known to the State of California to cause birth defects or other reproductive...

Page 3: ...plier call the fire department 4 This fireplace shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any other enclosed area 5 Do not use this fireplace...

Page 4: ...ocal codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 if applicable Available from American National Standards Institute Inc 25 West 43rd Street 4th floor...

Page 5: ...tal lation CLEARANCES Minimum clearances to combustibles for the fireplace are as follows Back and sides 1 26 mm Perpendicular walls 8 203 mm Floor From bottom of Fireplace 0 0 mm Ceiling From top of...

Page 6: ...E OF NAILING FLANGE 15 1 4 387 mm MOUNTED INSIDE OF NAILING FLANGE FLAT FOR ONE SIDED APPLICATION STUDS ARE NOT MOUNTED TO THE REAR OF NAILING FLANGES 17 1 2 445 mm Figure 2 Framing Clearances for One...

Page 7: ...1 mm 1 7 8 181 mm 1 26 mm 3 1 4 83 mm 8 1 4 210 mm 13 1 4 337 mm 1 7 8 181 mm 2 3 4 181 mm 44 1 8 1121 mm 55 1 8 1400 mm 47 1194 mm 52 1321 mm 5 8 16 mm 11 3 4 298 mm 16 1 2 419 mm 17 1 2 445 mm 8 1 4...

Page 8: ...ctrical housing and cover plate have sharp edges Wear protective gloves CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If you have conflicting gas types do not install fi...

Page 9: ...ee Checking Gas Connec tions Page 10 WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Check your building codes for any special requirements for locating equipment shutoff v...

Page 10: ...iance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage fireplace regulator 2 Cap off open end of gas pipe where equipm...

Page 11: ...ng bracket and replace screws FINISHING FIREPLACE FOR INSTALLATION The BerlinLights43 series fireplace come with the rear panel semi installed If you will be using the fireplace for a one sided regula...

Page 12: ...lications Figure 21 Installing Side Face Filler for See Thru Applications Removing Rear Interior Wall 1 Through firebox opening in the front of the fireplace unscrew 4 corner brackets from the firebox...

Page 13: ...e control module is located on the left as shown in Figure 24 5 Light switch is located on the right hand side as shown in Figure 24 6 ON OFF switch is located on the left hand side as shown in Figure...

Page 14: ...te transmit ter Once the module s internal receiver accepts the transmitter code there will be a series of confirming beeps The remote system is ready for use Pushing and holding the LEARN button for...

Page 15: ...ater This appliance requires 120V electricity for normal operation Control module should be plugged into electrical outlet located underneath firebox bottom Back up battery supply is available for pow...

Page 16: ...or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 above BURNER FLAME PA...

Page 17: ...AF 4000 AF 4000B P Control Module Black Black SWI SWI GND Red HI LO Main Black BATTERY PACK Black Red Black Red SIZE AA SIZE AA SIZE AA SIZE AA AC Power Adapter 110V MAX 15 AMPS CAUTION Label all wire...

Page 18: ...nlet gas pressure is too low 7 Burner orifice s clogged 8 Wire disconnected from gas control 9 Ground wire issue 1 Turn on gas supply or open equipment shutoff valve 2 Repeat igniting operation until...

Page 19: ...e Cleaning and Main tenance Page 19 or replace burner orifice s White powder residue forming within burner box or on adjacent walls or furniture 1 When heated vapors from furniture polish wax carpet c...

Page 20: ...s one beep every one second 1 The burner did not successfully ignite 1 Press OFF then ON buttons to re attempt ignition Refer to When on button on remote control is pressed there is spark at igniter b...

Page 21: ...LIGHTS43ZEP 1 2 4 4 4 4 5 8 6 7 3 9 10 11 19 20 21 12 12 13 14 4 22 15 16 18 17 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally appro...

Page 22: ...Tube X 3 8 MPT 2 11 J4711 Flextube Dormont 3 8 X 15 1 12 J6694 Gasket Burner Linear DV 2 13 J7946 Cover Electronics LVFO 1 14 RP126051 01 Insulation Heat Sheild LVF 1 15 J7945 Bracket Elec Mount LVFO...

Page 23: ...Astria us com 126776 01K 23 PARTS MODELS BERLINLIGHTS43ZEN AND BERLINLIGHTS43ZEP 5 5 1 1 2 2 7 8 9 8 9 10 10 11 7 12 17 14 3 6 13 13 15 4 16 16 1 1...

Page 24: ...or False 1 5 J7454 Flange Nailing Sides Linear 4 6 J4387 Electrical Duct Assembly 1 7 J6934 Cover Gas Conduit Plate 36E 2 8 J7516 Bracket Access Cover LVFO 2 9 J7628 Bracket Corner Wall LVFO 4 10 J737...

Page 25: ...nstallation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your fireplace ready You...

Page 26: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Page 27: ...fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal...

Page 28: ...nsult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126776 01 Rev K 11 2019 1769 East Lawrence Street Russellville AL 35654 P126776 01 Astr...

Reviews: