Astria Fireplaces BerlinLights43ZEN Installation And Operation Instructions Manual Download Page 2

Astria.us.com

126776-01K

2

SAFETY

Safety ............................................................................................. 2
Local Codes ................................................................................... 3
Requirements for the Commonwealth of Massachusetts............... 3
Product Identification ..................................................................... 4
Product Features ............................................................................ 4
Installation ..................................................................................... 5
Operation  .................................................................................... 15
Cleaning and Maintenance  .......................................................... 16
Inspecting Burners  ...................................................................... 16
Replacing Light Bulbs .................................................................. 16
Wiring Diagram ............................................................................ 17
Troubleshooting ........................................................................... 18
Parts ............................................................................................ 21
Specifications ............................................................................... 25
Replacement Parts ....................................................................... 25
Service Hints ................................................................................ 25
Technical Service ......................................................................... 25
Accessories .................................................................................. 25
Warranty ...................................................................................... 27

TABLE OF CONTENTS

Thank you for your purchase. We appreciate your 

business!

Please carefully read and follow all instructions in this manual. Pay 

special attention to all warnings and safety information.
Following these safety, care, and operation instructions will help 

ensure many years of dependable and enjoyable service from your 

fireplace.
Please read and understand these instructions before installing 

or operating.

  WARNING: Improper installation, adjustment, 

alteration, service or maintenance can cause prop-

erty damage, personal injury or loss of life. Refer to 

this manual for correct installation and operational 

procedures. For assistance or additional information 

consult a qualified installer, service agency or the 

gas supplier.

This fireplace is designed for outdoor use only. It has 

been tested and approved to ANSI Z21.97 / CSA 2.41 

standard for outdoor decorative gas appliance and 

CAN 1-2.21-M85 standard for gas-fired appliance for 

outdoor installation.

 DANGER: Carbon monoxide poisoning may lead 

to death!

 WARNING: This product can expose you to chemi-

cals including Carbon Black, which is known to the State 

of California to cause cancer, and Carbon Monoxide, 

which is known to the State of California to cause 

birth defects or other reproductive harm. For more 

information go to www.P65Warnings.ca.gov.

  WARNING: Any change to this fireplace or its 

controls can be dangerous.

Due to high temperatures, the appliance should be 

located out of traffic and away from furniture and 

draperies.

Clothing or other flammable materials should not 

be hung from the appliance or placed on or near the 

appliance. Never place any objects on the fireplace.

IMPORTANT: Read this owner’s manual carefully and 

completely before trying to assemble, operate or service 

this appliance. Improper use of this fireplace can cause 

serious injury or death from burns, fire, explosion, elec-

trical shock and carbon monoxide poisoning.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poison-

ing resemble the flu, with headaches, dizziness or nausea. If you have 

these signs, the fireplace may not be working properly. Get fresh air at 

once! Have heater serviced. Some people are more affected by carbon 

monoxide than others. These include pregnant women, people with 

heart or lung disease or anemia, those under the influence of alcohol 

and those at high altitudes.
Natural and Propane/LP Gas: Natural and propane/LP gases are 

odorless. An odor-making agent is added to the gas. The odor helps 

you detect a gas leak. However, the odor added to the gas can fade. 

Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual 

for reference. It is your guide to safe and proper operation of this 

fireplace.

 

Summary of Contents for BerlinLights43ZEN

Page 1: ...the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier D...

Page 2: ...e you to chemi calsincludingCarbonBlack whichisknowntotheState of California to cause cancer and Carbon Monoxide which is known to the State of California to cause birth defects or other reproductive...

Page 3: ...plier call the fire department 4 This fireplace shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any other enclosed area 5 Do not use this fireplace...

Page 4: ...ocal codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 if applicable Available from American National Standards Institute Inc 25 West 43rd Street 4th floor...

Page 5: ...tal lation CLEARANCES Minimum clearances to combustibles for the fireplace are as follows Back and sides 1 26 mm Perpendicular walls 8 203 mm Floor From bottom of Fireplace 0 0 mm Ceiling From top of...

Page 6: ...E OF NAILING FLANGE 15 1 4 387 mm MOUNTED INSIDE OF NAILING FLANGE FLAT FOR ONE SIDED APPLICATION STUDS ARE NOT MOUNTED TO THE REAR OF NAILING FLANGES 17 1 2 445 mm Figure 2 Framing Clearances for One...

Page 7: ...1 mm 1 7 8 181 mm 1 26 mm 3 1 4 83 mm 8 1 4 210 mm 13 1 4 337 mm 1 7 8 181 mm 2 3 4 181 mm 44 1 8 1121 mm 55 1 8 1400 mm 47 1194 mm 52 1321 mm 5 8 16 mm 11 3 4 298 mm 16 1 2 419 mm 17 1 2 445 mm 8 1 4...

Page 8: ...ctrical housing and cover plate have sharp edges Wear protective gloves CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If you have conflicting gas types do not install fi...

Page 9: ...ee Checking Gas Connec tions Page 10 WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Check your building codes for any special requirements for locating equipment shutoff v...

Page 10: ...iance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage fireplace regulator 2 Cap off open end of gas pipe where equipm...

Page 11: ...ng bracket and replace screws FINISHING FIREPLACE FOR INSTALLATION The BerlinLights43 series fireplace come with the rear panel semi installed If you will be using the fireplace for a one sided regula...

Page 12: ...lications Figure 21 Installing Side Face Filler for See Thru Applications Removing Rear Interior Wall 1 Through firebox opening in the front of the fireplace unscrew 4 corner brackets from the firebox...

Page 13: ...e control module is located on the left as shown in Figure 24 5 Light switch is located on the right hand side as shown in Figure 24 6 ON OFF switch is located on the left hand side as shown in Figure...

Page 14: ...te transmit ter Once the module s internal receiver accepts the transmitter code there will be a series of confirming beeps The remote system is ready for use Pushing and holding the LEARN button for...

Page 15: ...ater This appliance requires 120V electricity for normal operation Control module should be plugged into electrical outlet located underneath firebox bottom Back up battery supply is available for pow...

Page 16: ...or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 above BURNER FLAME PA...

Page 17: ...AF 4000 AF 4000B P Control Module Black Black SWI SWI GND Red HI LO Main Black BATTERY PACK Black Red Black Red SIZE AA SIZE AA SIZE AA SIZE AA AC Power Adapter 110V MAX 15 AMPS CAUTION Label all wire...

Page 18: ...nlet gas pressure is too low 7 Burner orifice s clogged 8 Wire disconnected from gas control 9 Ground wire issue 1 Turn on gas supply or open equipment shutoff valve 2 Repeat igniting operation until...

Page 19: ...e Cleaning and Main tenance Page 19 or replace burner orifice s White powder residue forming within burner box or on adjacent walls or furniture 1 When heated vapors from furniture polish wax carpet c...

Page 20: ...s one beep every one second 1 The burner did not successfully ignite 1 Press OFF then ON buttons to re attempt ignition Refer to When on button on remote control is pressed there is spark at igniter b...

Page 21: ...LIGHTS43ZEP 1 2 4 4 4 4 5 8 6 7 3 9 10 11 19 20 21 12 12 13 14 4 22 15 16 18 17 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally appro...

Page 22: ...Tube X 3 8 MPT 2 11 J4711 Flextube Dormont 3 8 X 15 1 12 J6694 Gasket Burner Linear DV 2 13 J7946 Cover Electronics LVFO 1 14 RP126051 01 Insulation Heat Sheild LVF 1 15 J7945 Bracket Elec Mount LVFO...

Page 23: ...Astria us com 126776 01K 23 PARTS MODELS BERLINLIGHTS43ZEN AND BERLINLIGHTS43ZEP 5 5 1 1 2 2 7 8 9 8 9 10 10 11 7 12 17 14 3 6 13 13 15 4 16 16 1 1...

Page 24: ...or False 1 5 J7454 Flange Nailing Sides Linear 4 6 J4387 Electrical Duct Assembly 1 7 J6934 Cover Gas Conduit Plate 36E 2 8 J7516 Bracket Access Cover LVFO 2 9 J7628 Bracket Corner Wall LVFO 4 10 J737...

Page 25: ...nstallation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your fireplace ready You...

Page 26: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Page 27: ...fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal...

Page 28: ...nsult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126776 01 Rev K 11 2019 1769 East Lawrence Street Russellville AL 35654 P126776 01 Astr...