Continued

The draft shield kit should be installed after the fireplace is completely 

framed and finished. The brackets are attached to the front side face 

of the fireplace using two screws as shown in Figure 25a. Position 

the glass panel in the bracket so that it is securely in place. The glass 

panel can be placed in two different height locations.

GAS CONTROL MODULE SYSTEM
REMOTE CONTROL FEATURE
The module has a built in remote control receiver that allows the 

user to program the remote transmitter at any time during or after 

the installation of the burner.
1.  There is a switch located on the right side of the module that 

reads REMOTE/OFF (Figure 26).

2.  When the remote/off switch is in the OFF position, the burner 

will operate from the rocker switch or wall switch connected to 

the two BROWN wires on the module.

3.  When the remote/off is in the REMOTE position the burner will 

operate from the Remote Control Transmitter.

NOTE:  The module must be programmed to the Remote Control 

Transmitter.
•  To program the module (make sure the system has power), 

locate the learn button (Figure 27) on the module. Locate the 

metal shield that is covering the module and remove the screw 

on top. Use a small thin object like a paper clip (not sharp points) 

to press and release the learn button. There will be a beep sound 

from the module. Then press any button on the remote transmit-

ter. Once the module's internal receiver accepts the transmitter 

code, there will be a series of confirming beeps.

•  The remote system is ready for use.

•  Pushing and holding the LEARN button for 6 seconds will result 

in clearing the transmitter security code from the module's 

memory. The module will make three long beeps in succession 

when it has been cleared.

Figure 27 - Gas Module Left Side

IGNITER ASSEMBLY
The igniter assembly is factory preset for proper ignition of the burner. 

Alterations may have occurred during shipping and handling. Call a 

qualified service person to readjust the igniter assembly if necessary.
The igniter should be positioned as shown in Figure 28.
NOTE: Figure 28, shows the correct positioning of the igniter and 

sensing rod.
If your igniter assembly does not meet these requirements:
•  turn appliance off (see To Turn Off Gas to Appliance, Page 15).
• see Troubleshooting, Page 18.

Figure 28 - Igniter 

NOTE: Reference only, not to scale

Igniter

Ground 

Electrode

Sensing 

Rod

0.8000

Spark Gap 

0.120

Figure 25a - Installing Draft Shield Kit 

Glass Panel

Bracket

Screws

Figure 26 - Gas Module Right Side

Continuous Pilot

Off/On Switch

Remote/Off 

Switch

“S” Pilot 

Connection

“I” Pilot 

Connection

ADJ.

 

Learn Button

AUX Connection

  WARNING: Do not change or substitute glass 

pebbles provided with this fireplace. If replacing, use 

only replacement glass pebbles. See Parts 

Page 22

.

Discontinue use of the appliance immediately if glass panel is 

damaged and contact a qualified installer for repair. Only glass 

panel certified with the appliance shall be used.

DRAFT SHIELD KIT INSTALLATION (F1031)

Summary of Contents for BerlinLights43ZEN

Page 1: ...the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier D...

Page 2: ...e you to chemi calsincludingCarbonBlack whichisknowntotheState of California to cause cancer and Carbon Monoxide which is known to the State of California to cause birth defects or other reproductive...

Page 3: ...plier call the fire department 4 This fireplace shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any other enclosed area 5 Do not use this fireplace...

Page 4: ...ocal codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 if applicable Available from American National Standards Institute Inc 25 West 43rd Street 4th floor...

Page 5: ...tal lation CLEARANCES Minimum clearances to combustibles for the fireplace are as follows Back and sides 1 26 mm Perpendicular walls 8 203 mm Floor From bottom of Fireplace 0 0 mm Ceiling From top of...

Page 6: ...E OF NAILING FLANGE 15 1 4 387 mm MOUNTED INSIDE OF NAILING FLANGE FLAT FOR ONE SIDED APPLICATION STUDS ARE NOT MOUNTED TO THE REAR OF NAILING FLANGES 17 1 2 445 mm Figure 2 Framing Clearances for One...

Page 7: ...1 mm 1 7 8 181 mm 1 26 mm 3 1 4 83 mm 8 1 4 210 mm 13 1 4 337 mm 1 7 8 181 mm 2 3 4 181 mm 44 1 8 1121 mm 55 1 8 1400 mm 47 1194 mm 52 1321 mm 5 8 16 mm 11 3 4 298 mm 16 1 2 419 mm 17 1 2 445 mm 8 1 4...

Page 8: ...ctrical housing and cover plate have sharp edges Wear protective gloves CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If you have conflicting gas types do not install fi...

Page 9: ...ee Checking Gas Connec tions Page 10 WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Check your building codes for any special requirements for locating equipment shutoff v...

Page 10: ...iance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage fireplace regulator 2 Cap off open end of gas pipe where equipm...

Page 11: ...ng bracket and replace screws FINISHING FIREPLACE FOR INSTALLATION The BerlinLights43 series fireplace come with the rear panel semi installed If you will be using the fireplace for a one sided regula...

Page 12: ...lications Figure 21 Installing Side Face Filler for See Thru Applications Removing Rear Interior Wall 1 Through firebox opening in the front of the fireplace unscrew 4 corner brackets from the firebox...

Page 13: ...e control module is located on the left as shown in Figure 24 5 Light switch is located on the right hand side as shown in Figure 24 6 ON OFF switch is located on the left hand side as shown in Figure...

Page 14: ...te transmit ter Once the module s internal receiver accepts the transmitter code there will be a series of confirming beeps The remote system is ready for use Pushing and holding the LEARN button for...

Page 15: ...ater This appliance requires 120V electricity for normal operation Control module should be plugged into electrical outlet located underneath firebox bottom Back up battery supply is available for pow...

Page 16: ...or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 above BURNER FLAME PA...

Page 17: ...AF 4000 AF 4000B P Control Module Black Black SWI SWI GND Red HI LO Main Black BATTERY PACK Black Red Black Red SIZE AA SIZE AA SIZE AA SIZE AA AC Power Adapter 110V MAX 15 AMPS CAUTION Label all wire...

Page 18: ...nlet gas pressure is too low 7 Burner orifice s clogged 8 Wire disconnected from gas control 9 Ground wire issue 1 Turn on gas supply or open equipment shutoff valve 2 Repeat igniting operation until...

Page 19: ...e Cleaning and Main tenance Page 19 or replace burner orifice s White powder residue forming within burner box or on adjacent walls or furniture 1 When heated vapors from furniture polish wax carpet c...

Page 20: ...s one beep every one second 1 The burner did not successfully ignite 1 Press OFF then ON buttons to re attempt ignition Refer to When on button on remote control is pressed there is spark at igniter b...

Page 21: ...LIGHTS43ZEP 1 2 4 4 4 4 5 8 6 7 3 9 10 11 19 20 21 12 12 13 14 4 22 15 16 18 17 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally appro...

Page 22: ...Tube X 3 8 MPT 2 11 J4711 Flextube Dormont 3 8 X 15 1 12 J6694 Gasket Burner Linear DV 2 13 J7946 Cover Electronics LVFO 1 14 RP126051 01 Insulation Heat Sheild LVF 1 15 J7945 Bracket Elec Mount LVFO...

Page 23: ...Astria us com 126776 01K 23 PARTS MODELS BERLINLIGHTS43ZEN AND BERLINLIGHTS43ZEP 5 5 1 1 2 2 7 8 9 8 9 10 10 11 7 12 17 14 3 6 13 13 15 4 16 16 1 1...

Page 24: ...or False 1 5 J7454 Flange Nailing Sides Linear 4 6 J4387 Electrical Duct Assembly 1 7 J6934 Cover Gas Conduit Plate 36E 2 8 J7516 Bracket Access Cover LVFO 2 9 J7628 Bracket Corner Wall LVFO 4 10 J737...

Page 25: ...nstallation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your fireplace ready You...

Page 26: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Page 27: ...fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal...

Page 28: ...nsult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126776 01 Rev K 11 2019 1769 East Lawrence Street Russellville AL 35654 P126776 01 Astr...

Reviews: