37
EN
DIP switch
DIP
Position Effect
1
ON
Terminating resistor
1
OFF
no terminating resistor
2
ON
Hi-O group 1
2
OFF
Hi-O group 0
SYSCON4
Description
1
VB +
2
CAN H
3
CAN L
4
VB –
SYSCON7
Description
7
Output 3
Black
Open collector
6
Vcc
Red
5
Output 5
grey
Open collector
4
Output 6
Brown
Open collector
3
Output 4
Blue
Open collector
2
VB –
Yellow
1
VB +
green
Note!
The connecting cable to SYSCON7 must be processed:
in order to use the OC
outputs, the plug must be used and cut through at the other end (PIN 1/3/4 or 5,
depending on the OC output to be used). Afterwards, the signal to be controlled
is connected with an on-site connecting clamp.
ON
21
9
51
3
CTS
1
2
4 VB- 3 CAN
L
2 CAN
H
1 VB+
7 Ausgang 3
6 Vcc
5 Ausgang 5
4 Ausgang 6
3 Ausgang 4
2 VB-
1 VB+