The classification key describes the properties of locks according to EN 179
Tab. 5 explains the classification key.
Class
Meaning
3
High frequency of use and little incentive for care, i.e. in areas where the possibility of accident
or misuse exists
7
200,000 test cycles
6
Door weight up to 200 kg
B
Suitable for use on fire doors and smoke doors when tested in accordance with EN 1634-1
1
Suitable for critical safety functions
3
High corrosion resistance in accordance with EN 1670:2007 Section 5.6
2
Burglary protection up to 1000 N
2
Up to 100 mm projection (standard projection) of the control
A
Handle-operated emergency exit lock
B
For installation in a single-leaf door only opening outwards
CE identification marking
C
ASSA ABLOY (Schweiz) AG
Schlosstechnik
Laufenstrasse 172
4245 Kleinlützel
SWITZERLAND
0757-CPR-229PANIK-6039631-23-3
2018
EN 179: 2008
3
7
6
B
1
3
2
2
A
B
—
Tab. 5 :
Classification key
according to EN 179
Summary of Contents for MSL 25574PE-SV
Page 19: ...19 Montage DE Abb 6 Sachschaden vermeiden 1 2 1 2 max 150 N ...
Page 23: ...23 Montage DE Schloss manuell prüfen Abb 9 Manuelle Funktionsprüfung 1 2 3 4 5 ...
Page 55: ...55 Assembly EN Fig 6 Prevent material damage 1 2 1 2 max 150 N ...
Page 59: ...59 Assembly EN Checking the lock manually Fig 9 Manual function testing 1 2 3 4 5 ...
Page 91: ...91 Montage FR Fig 6 Éviter les dommages matériels 1 2 1 2 max 150 N ...
Page 95: ...95 Montage FR Contrôle manuel de la serrure Fig 9 Contrôle fonctionnel manuel 1 2 3 4 5 ...
Page 127: ...127 Montaggio IT Fig 6 Evitare danni materiali 1 2 1 2 max 150 N ...
Page 146: ...146 IT Problema causa soluzione ...