16
Access 600 M802
Installation Instructions
FE6600/BL6600/MP6600 Series Multi-point Lock
FM452 07/20
Copyright © 2017, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
7
Installation Instructions, continued
j
Connect ElectroLynx
1. Connect P3 (2-pin connector) from lock
body to J3 on interior PCB assembly.
2. Connect P4 (6-pin connector) from lock
body to J4 on interior PCB assembly.
3. Connect P5 (7-pin connector) from Reader
board to J5 on interior PCB assembly.
4. Connect ElectroLynx harness (4 and 8-pin)
from door harness to ElectroLynx harness on
interior PCB assembly.
NOTE:
Connectors go on only one way. Do not
offset connector. They must be completely
seated.
J1
J2
From Lock
Body P4 to J4
From Lock
Body P3 to J3
From Reader
Board P5 to J5
To ElectroLynx
Harness
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
J2
J1
1-Violet Lock
Neg
(Actuator, neg)
3-Pink
DPS (NC)
1- Black
PWR NEG
3-White
DATA 1
5-Orange
RX (NO/
NC)
7-Brown
EGND
2-Gray Lock Pos
(Actuator, pos)
4-Tan
DPS (COM)
2-Red
PWR POS
4-Green
DATA 0
6-Blue
RX (COM)
8-Yellow
LED
k
Position Outside Wires
To prevent any damage caused by pinching wires, follow these steps prior to installing inside escutcheon
assembly:
1. Insert the ElectroLynx connectors (8 and 4-pin) and establish their position inside the door prep
(Figure 5).
2. Neatly fold the wires onto themselves and into the remaining space to prevent pinching of wires
when mounting escutcheon (Figure 6). Do not tuck extra mortise lock body wires back inside the
lock body cylinder hole.
Figure 5
Figure 6