19
Access 600 M802
Installation Instructions
FE6600/BL6600/MP6600 Series Multi-point Lock
FM452 07/20
Copyright © 2017, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
8
Operational Check, continued
b
Electrical Operational Check
NOTE:
Once electrical wiring has been successfully
completed according to proper application, follow
the following steps:
1. Turn power ON.
2. Verify LED located on reader is ON (Red or Green
depending on reader configuration (See reader
LED Configuration).
3. Present proximity credential and verify LED and
sounder activity.
4. Verify valid card read at EAC panel.
5. Verify system operation functions; i.e. , present
Prox credential to reader and unlock door.
c
Wiegand Test Unit
Feature
WT1
WT2
12 or 24VDC solenoid
lock voltage adjustable
X
X
Operates as Fail Safe or
Fail Secure
X
X
"Learn" mode allows
testing of specific cards
without programming at
the panel level
X
X
Card reader data integrity
is validated at test unit
X
X
Works with SE LP10
X
X
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
X
Displays measured end-
of-line resistor values (if
applicable)
X
The ASSA ABLOY Wiegand Test Unit verifies your
installation in the field. The test unit checks for
proper wiring, card reader data integrity, lock
functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demon-
stration abilities to highlight the product’s featu-
res and capabilities.