12
Access 600 M802
Installation Instructions
FE6600/BL6600/MP6600 Series Multi-point Lock
FM452 07/20
Copyright © 2017, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
7
Installation Instructions, continued
d
Con
fi
gure the DIP Switch Settings
e
Install Lock Body
DIP Switch
1 2 3
Handing
RH & RHR
LH & LHR
Actuator Operation
Fail Safe
Fail Secure
RX Output
Normally
Open
Normally
Closed
Check Polarity:
(red wire)
IMPORTANT:
This product is built and factory tested to the configuration specified. Any change to the
3-position DIP-switch settings located at the bottom of the mortise lock body must be made prior to
lock installation.
NOTE:
Do not pull the lock into the pocket using the harness alone.
Ensure that the wire harness is not pinched between the lock and the mortise pocket.
1. Feed the wire harness into the mortise pocket and
through inside preparation hole as shown below.
2. Carefully push the lock body into the pocket
while lightly applying tension to the wire harness.
3. Insert (2) #12-24 screws into the
lock body and tighten* with a
screw driver.
*Do not fully
tighten until levers
are installed and
properly aligned.
(2) #12-24
screws
Wire
Harness
Ground
Wire