Product Warranty 

The manufacturer disclaims all implied and express warranties, including the implied warranty of merchantability and the implied warranty of fitness for a particular purpose, 

except as follows: This condensate product purchased by you concurrently is unconditionally warranteed to be free from defects in material and workmanship under normal use for a period of two 

years from date of purchase, providing it is installed and operated strictly in accordance with the manufacturer’s installation instructions. If the product is found to be defect or otherwise fails in 

normal use, you may return it for replacement. All freight charges for the return of the product shall be borne by you. The manufacturer will pay outgoing freight charges for the replacement product. 

Defective product returned to the factory prepaid will be repaired or replaced free of charge. Replacement product will, to the extent such product is then available in the manufacturer’s inventory, be 

of a similar type of color and kind. Manufacturer retains the right to substitute product if the replacement product does not conform in terms of color, type and specifications to the original product 

if no longer available. This warranty does not cover replacement labor or any cost, claim or incident to any defect nor does it cover any consequential damages. The sole liability of the manufacturer 

under this warranty is limited to the replacement of defective product. Product damaged by improper use, accident, neglect, alteration, abuse or improper installation is excluded from this warranty.

 

Designed for surface installatión under minisplit 

evaporator / Diseñada para sujetarse a una superficie, 

directamente debajo del evaporador

 

Quick and easy to install / Rápido y fácil de instalar

 

Quietly and reliably pumps condensate to a maximum 

height of 33 feet / Bombea el agua de condensado hasta 

una altura de 33 pies de manera silenciosa y confiables

Thank you for buying your new Mini White Pump. 

This manual provides complete instructions for installation 

and maintenance which should be carefully followed. Please record following information for future reference: / 

Agradecemos su compra de la nueva bomba Mini White. 

Éste manual proporciona las instrucciones completas que 

deben de seguirse cuidadosamente para la correcta instalación y mantenimiento de la bomba. Anote la información 

siguiente para una referencia futura.

Serial number: 

Operating voltage:

Número de serie: 

Voltaje operativo:                

Date installed:    

Location of pump:   

Fecha de instalación: 

Ubicación de la bomba:

Imported and Distributed by: / Importado y distributado para:
2601 Spenwick Drive, Houston, TX 77055  Tel: 800-231-3345  Fax: 800-441-0051  www.rectorseal.com

INSTALLATION & MAINTENANCE MANUAL / MANUAL DE INSTALACIÓN Y MANTENIMIENTO

Summary of Contents for mini white

Page 1: ...ranty does not cover replacement labor or any cost claim or incident to any defect nor does it cover any consequential damages The sole liability of the manufacturer under this warranty is limited to...

Page 2: ...N EMBARGO BAJO CIERTAS CONDICIONES CUANDO LOS NIVELES DE RUIDO AMBIENTE SEAN EXTREMADEMENTE BAJOS EL SONIDO DE SU OPERACI N INTERMITENTE PUEDE QUE SE PERCIBA COMO RUIDOSO Y LA BOMBA PUEDE SER COLOCAR...

Page 3: ...scharge hose watertight 14 Is pump level 15 Is float in position 16 Is magnet facing upwards on float 17 Is filter present in reservoir 18 Has provision been made to prevent siphoning 19 Is drain disc...

Page 4: ...IS NOT FAIL SAFE AND MAY CAUSE AN OVERFLOW WIRING 1 Check that pump voltage conforms with evaporator voltage and that actual voltage supplied is sufficient to drive pump 2 Wire pump power cable to inc...

Page 5: ...ea 1 terminal block in condenser bloque de terminales en condensador 1 amp fuse 1 amp fusible terminal block in evaporator bloque de terminales en evaporador incoming 208 230V AC power terminals perma...

Page 6: ...uch as Coil Rite Reservoir must be replaced flat and horizontal after removal for any reason Ensure that float is replaced with magnet facing upwards ALLOW ONLY ASPEN APPROVED COIL CLEANERS TO COME IN...

Page 7: ...ha instalado material de relleno insonorizante y antivibraci n adecuado entre la bomba y las superficies de contacto Falla Condensaci n en condiciones h meda 1 Est aislado el primer tramo de 6 de la...

Page 8: ...TE LA OPERACI N DE ESTAS BOMBAS ES NECESARIO ENTENDER ALGUNOS DE SUS PRINCIPIOS B SICOS DE OPERACI N Todas las bombas de pist n para minisplit comparten algunas caracter sticas comunes 1 Son autoceban...

Page 9: ...DEL CASO 4 COMPROBAR QUE EL VOLTAJE DE LA BOMBA CUMPLEAN CON EL VOLTAJE DE SUMINISTRO DEL EVAPORADOR ANTES DE COMENZAR LA INSTALACI N 5 INSTALE PONGA TUBER AS Y CABLES ESTRICTAMENTE EN CONFORMIDAD CO...

Page 10: ...SUPPLIED OR BY INSTALLING THE DISCHARGE HOSE CORRECTLY WITH AN AIR GAP EITHER OF WHICH WILL EQUALIZE THE ATMOSPHERIC PRESSURE AND ELIMINATE THE SIPHONING EFFECT INCORRECT Failure to follow correct Di...

Page 11: ...sifonaje o Escape de Aire a no m s de 6 de la bomba SE DEBE INSTALAR Dispositivo Antisifonaje o Escape de Aire a no m s de 6 de la bomba PRESI N ATMOSFERICA PRESI N ATMOSFERICA PRESI N ATMOSFERICA PRE...

Page 12: ...e fijaci n a FIXING HOLES FOR PUMP ASSEMBLY ON WALL b OPENING REQUIRED ON BOTTOM OF EVAPORATOR 3 L x 1 5 W c CUT OFF MARK FOR INSULATED DRAIN HOSE FROM EVAPORATOR a UBICACI N DE ORIFICIOS NECESARIOS P...

Page 13: ...Locking refrigerant caps Big Foot AC rooftop mounting system RectorSeal AC equipment mounting Slimduct Condensate drain hose HVAC ACCESSORY PRODUCT LINE RectorSeal 2601 Spenwick Drive Houston TX 77055...

Reviews: