27
Para-
meter
Name
Factory
preset
Min
va-
lue
Max
va-
lue
Signifi es
P105
Language
1
0
7
Swedish
For setting, see page 8
P115
Child lock On/Off
0
0
1
Off.
Value 1 = Child lock ON
P2011
Min drying time
Aut40°
35 (min)
10
45
Regardless of moisture level, the drying process
runs 35 min.
Factory preset.
P2012
Max drying time
Aut40°
360 (min)
60
360
Regardless of moisture level, the drying process
runs 360 min.
Factory preset.
P2013
Max temp
Aut40°
51°
41°
61°
The heating elements switch off if the value is
exceeded.
P2014
Exhaust temp.
process fi nished
Aut40°
38°
34°
54°
For Normal programmes the drying process
ends with cooling.
For Extra programmes the extra drying time
starts, followed by cooling.
P2015
Extra drying time
Aut40°
30 (min)
10
45
Extra programme drying time after exhaust temp.
has been reached.
P2016
Cooling time
Aut40°
10 (min)
2
20
Time when only the fan is in operation, without
heating elements. Provides more even drying time.
P2021
Min drying time
Aut60°
35 (min)
15
45
Regardless of moisture level, drying process
runs 35 min.
Factory preset.
P2022
Max drying time
Aut60°
240 (min)
60
360
Regardless of moisture level, drying process
runs 240 min.
Factory preset.
P2023
Max temp
Aut60°
90°
61°
100°
The heating elements switch off if the value is
exceeded.
P2024
Outlet temp.
process fi nished
Aut60°
48°
40°
73°
For Normal programmes the drying process
ends with cooling.
For Extra programmes the extra drying time
starts, followed by cooling.
P2025
Extra drying time
Aut60°
30 (min)
10
45
Extra programme drying time after exhaust temp.
has been reached.
P2026
Cooling time
Aut60°
10 (min)
2
20
Time when only the fan is in operation, without
heating elements. Provides more even drying time.
PARAMETER LIST