The stove must be placed on solid concrete, solid masonry, or when installed on a combustible floor, on a floor protector. The floor
protector is required to provide heat, live ember, and ash protection and must be of a non-combustible, continuous solid surface to
protect against infiltration of live embers and ash. The stove must be placed on solid concrete, solid masonry, or when installed on a
combustible floor, on a Type 2 floor protector listed to standard UL 1618 with a minimum R value of 1.03 and a minimum thickness
of 1/2” or equivalent.
Dimension
Inch
mm
H*
Front
16
407
J
Flue rear
2
51
K**
Left
6
204
L**
Right
6
204
M
Flue Side
2
51
⃰ Canadian installations require 18” (457mm)
⃰ ⃰ Canadian installations require 8” (203mm)
SPECIAL MOBILE HOME REQUIREMENTS
U
WARNING! - Do not install in a sleeping room
U
CAUTION! - The structural integrity of the mobile
home floor, wall, and ceiling/roof must be maintained
.
In addition to the previously detailed installation requirements,
mobile home installations must meet the following requirements:
• The heater must be permanently attached to the floor.
1.
There are two holes in the pedestal base, use 3/8” bolts
through the floor.
2.
To attach the leg model use two 3/8-16 UNC bolts
through the floor.
• The heater must be electrically grounded to the steel chassis
of the mobile home with 8 GA copper wire using a serrated or
star washer to penetrate paint or protective coating to ensure
grounding.
• When moving your mobile home, all exterior venting must
be removed while the mobile home is being relocated. After
relocation, all venting must be reinstalled and securely fastened.
• Outside Air is mandatory for mobile home installation. See
your dealer for purchasing.
• Check with your local building officials as other codes may
apply.