EN
25
ASIN AQUA maintenance
To ensure the optimum effi
ciency, perform visual checks and maintenance
of ASIN AQUA Net on a regular basis.
Pump Hose Replacement
To prevent the pump from failing, it is recommended to replace the hose
#12073 every 24 months.
In doing so, proceed as follows:
•
Switch off ASIN AQUA Net.
•
Turn the pump cover cassette counterclockwise and take
it out of ASIN AQUA.
•
Release both hose ends and take it out of the cassette.
•
Lubricate the new hose with the supplied special grease.
•
Insert the lubricated hose into the cassette.
•
Place the cover cassette back on ASIN AQUA Net and turn it clockwise
to lock it.
•
Use new nuts, which are part of the replacement hose set, for connection
of the PE tube.
Injection Valve Maintenance
On a regular basis, check throughput of the injection valves, rubber band
integrity, remove scale.
In case of private pools, replace injection valve rubber bands every 2 years.
In case of public pools, replace injection valve rubber bands every year.
pH Probe Maintenance
Take the pH probe out of ASIN AQUA Net housing and clean it from impurities.
Follow the instructions attached to the used probe.
Flowmeter with fi lter
Rinse the fl ow meter sieve regularly.
#12073 Replacement tube kit for PP 60
#12005 Injection valve
#13087
Injection valve
replacement fl ap