ASIN AQUA Net error messages
Error messages:
The agent has run out.
•
Check the chlorine and pH agents regularly so that they
do not run out. Chlorine agent concentration is
15-20%. This degrades over time and if exposed to
direct sunlight.
The dosing pump does not work.
•
Check that your dosing pumps are securely fi tted and
not loose.
•
Check the connections to your dosing pumps are
secure and not leaking.
•
Check the clear plastic tubes inside the dosing pumps
are not damaged or broken.
•
To remove your dosing pumps from your ASIN AQUA,
disconnect the clear plastic tubes, turn your dosing
pump counterclockwise and pull away from your
ASIN AQUA.
The dosing valve is not working.
•
Check your dosing valves regularly for the build
up of limescale.
•
Make sure dust and dirt does not get into the
containers of the chlorine and pH agent to avoid
blockages and damage to the valves.
•
Check the rubber seals of your valves regularly
to prevent leaking.
Water does not fl ow to the probes.
•
Check the clear plastic tubes connection of your
ASIN AQUA for damage and leaks.
•
Check the connection of the clear plastic tubes to the
valves for damage and leaks.
•
Check the valves are properly connected to the water
supply and that they are not damaged, blocked or in the
closed position.
The probe does not work.
•
Replace the pH probe each year.
•
Ensure your probes are clean and free from dirt.
•
Exposure to below 0° C conditions damages
the probes.
•
Regular cleaning of the probes maintains
system accuracy.
After
30
doses
of chlorine
agent without
probe response
displays this error
message.
After
10/15/25
doses of pH agent
without probe
response displays
this error message.