EN
13
Pool Chemicals
Connection
Screw the
injection valves
into the plug D = 50 with thread G1 / 4 “# 12134,
glued to the T-piece.
Tighten by hand only. Do not use pliers or other tools.
Connect the
pH INJECTION VALVE
to the piping behind the fi lter and behind
VE
drainage of the measured water.
Connect the
CHLOR PURE INJECTION VALVE
behind the INJECTION VALVE,
VE
this prevents scale formation.
to connect reagents to ASIN AQUA use PE pipe 1/4 “(6.35 mm) # 12008,
which is part of the delivery.
CANISTER CONNECTION
Drill 6.35 mm and 1 mm diameter holes in the
canister cap. Pass the pipe through the cap so that it reaches to the bottom
of the canister. Place the suction basket at the end of the pipe.
PUMP CONNECTION
connect the suction of the pump on the left to the
canister connect the pump discharge on the right to the injection valve.
INJECTION VALVE CONNECTION
Pass the pipe through the nut, thread
the pipe onto the injection valve and tighten the nut fi rmly by hand.
Ø 1 m
m
Ø 6
,3
5 m
m
1
2
3
4
5
5
4
3
WARNING
To ensure that the joints are tight, cut the PE tube at an angle of 90 °.
Use special pliers # 13325 to cut plastic tubes. The cut must be clean
and smooth. Do not use ordinary scissors or knives!
WARNING
NEVER CONNECT pH minus reagent to disinfection pump or
disinfectant to pH pump!
In the case of a cross-connection, after ten doses
ASIN AQUA displays an error message. Repair the piping installation and then
you can continue to operate your ASIN AQUA.
Plug with