4. Wait at least 1 hour. Optimally up to 24 hours.
Before opening the water supply
to the probes, the water must be
ply
clean
and the
chlorine concentration
measured by the colorimeter or Pool Tester
must be within the range
0.3 to 1.2 mg/l
.
If the
concentration is lower
, repeat superchlorination. If the
concentration
is higher
, wait till the chlorine concentration in the water drops down.
5. Open the water supply to the probes
The „No water supply to the probes“ notifi cation will disappear from the ASIN
AQUA display.
6. pH adjustment
•
Set the required pH value ideally close to the pH value of the incoming
water.
•
ASIN AQUA Net adjusts the pH automatically according to the preset
required value.
•
The ideal pH value should be between 6.8 and 7.5.
7. Depending on the type of a probe you have,
proceed according to the chapter:
•
If you have the CLF probe
•
If you have the REDOX probe